RE 15300-WA, Version 06.2021,
Bosch Rexroth AB
Installation
31/72
Fig. 24: Installation instruction for articulated connection for TC A
1
x ≤ ± 2 mm (0,079 inch) misalignment in installation.
x ≤ ± 15 mm (0,59 inch) movement when in use.
2
The spherical plain bearing must be dismounted during welding. See
and the articulated connection must be disconnected.
3
Steel: EN 10025-3 – S355N (1.0545), Protected against corrosion, after welding.
2
3
1
Fr
Alternative position
DD00079192
Note!
Grounding
point for
welding
Table 9: External forces single ended torque arm valid for a pressure difference of 420 bar
[6000 psi] static
T
Fb
Fr
Pushing
Fig. 25: External forces Fr, Fb for TC A
DD00079195
T=Torque direction
on driven shaft
Torque arm
Motor
Force Fb
Force Fr
1)
N
lbf
N
lbf
TC A 2000
CBM 2000 2000
420 000
94 419.76
375 845
84 493.32
TC A 4000
CBM 3000 3000
308 000
69 241.15
251 553
56 551.36
TC A 4000
CBM 4000 4000
560 000
125 893.00
495 705
111 438.90
1)