R911418827, Edition 01, 5 / 8

Word 1

INT

IN

Channel 1 Value

Word 2

 

Byte 1

 
 

Bit 0
Bit 1
Bit 2-3
Bit 4-5

IN
IN
IN
IN
IN
IN

 
 

Channel 1 Wire break
Channel 1 Overrange
Channel 1 Limit 1
Channel 1 Limit 2

Word 3

INT

IN

Channel 2 Value

Word 4

 

Byte 1

 
 

Bit 0
Bit 1
Bit 2-3
Bit 4-5

IN
IN
IN
IN
IN
IN

 
 

Channel 2 Wire break
Channel 2 Overrange
Channel 2 Limit 1
Channel 2 Limit 2

Word 5

INT

IN

Channel 3 Value

Word 6

 

Byte 1

 
 

Bit 0
Bit 1
Bit 2-3
Bit 4-5

IN
IN
IN
IN
IN
IN

 
 

Channel 3 Wire break
Channel 3 Overrange
Channel 3 Limit 1
Channel 3 Limit 2

Word 7

INT

IN

Channel 4 Value

Word 8

 

Byte 1

 
 

Bit 0
Bit 1
Bit 2-3
Bit 4-5

IN
IN
IN
IN
IN
IN

 
 

Channel 4 Wire break
Channel 4 Overrange
Channel 4 Limit 1
Channel 4 Limit 2

Word 9

 

Byte 1

 
 

Bit 0
Bit 1

IN
IN
IN
IN

 
 

Periphery voltage ok
Error

Table 1: Standard representation

To directly arrange the status bits one after another and thus

to  reduce  the  amount  of  filling  bites,  select  "Channel  x  com-

pact" as well as "Device state compact" in the Engineering.
Process  data  consists  of  the  input  value  and  the  diagnostic

data in the "Compact" representation:

Word 1

INT

IN

Channel 1 Value

Word 2

INT

IN

Channel 2 Value

Word 3

INT

IN

Channel 3 Value

Word 4

INT

IN

Channel 4 Value

Word 5

 

Byte 1

 
 
 
 
 
 

Byte 2

 
 

Bit 0
Bit 1
Bit 2
Bit 3
Bit 4-5
Bit 6-7

 

Bit 2
Bit 3
Bit 4-5
Bit 6-7

IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN

 
 

Periphery voltage ok
Error
Channel 1 Wire break
Channel 1 Overrange
Channel 1 Limit 1
Channel 1 Limit 2

 

Channel 2 Wire break
Channel 2 Overrange
Channel 2 Limit 1
Channel 2 Limit 2

Word 6

 

Byte 1

 
 
 
 

Byte 2

 
 

Bit 2
Bit 3
Bit 4-5
Bit 6-7

 

Bit 2
Bit 3
Bit 4-5
Bit 6-7

IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN

 
 

Channel 3 Wire break
Channel 3 Overrange
Channel 3 Limit 1
Channel 3 Limit 2

 

Channel 4 Wire break
Channel 4 Overrange
Channel 4 Limit 1
Channel 4 Limit 2

Table 2: "Comact" figure

8

Diagnostic strategy

8.1 Mechanisms

Different  mechanisms  are  used  for  the  diagnostics  of  the

module.

Mechanism

Diagnostics

EtherCAT state machine
EtherCAT hardware watchdog

EtherCAT system diagnostics

Diagnostic objects in the CoE

object directory
10F1

Extended diagnostics, e.g.

peripheral errors
Error settings

Diagnosis history object

10F3

20 diagnostic messages can

be stored
Diagnosis history

Module status LED

Shows the general module

status

Channel status LED

Signals the channel status or

the error states

Содержание Rexroth ctrlX I/O XI332204

Страница 1: ...onnection method Push in XI332204 Connection method 2 wire shielded twisted in pairs Signal type Differential Input signal 0 mA to 20 mA Input resistance 250 Ω Limit frequency of input filter 15 7 kHz Conversion time 100 μs Resolution D A 16 bits incl sign Accuracy Typ 0 1 of the end value of the measured range MBE Max 0 3 of MBE Overload protection No max DC 10 4 V Imax 46 mA Common Mode Max 35 V...

Страница 2: ...sheet is only intended for qualified electricians and staff trained by these qualified electricians The user has to be familiar with the known safety concepts on automation technology applicable standards and other guidelines 4 3 Electric safety NOTICE Loss of electric safety Unintended handling can affect the device safety Observe the notes in the present data sheet during installation com missio...

Страница 3: ...x0 02 User offset Note that possible limitations of the value range also remain after the User scale limitation For more detailed informa tion refer to The settings can only be made in the Pre Op state and should be written upon each start of the EtherCAT bus via the start parameter Example 1 Module is XI422204 analog output with 10 V The target is to reduce the value range to values between 3V an...

Страница 4: ... for parameterization The module can be parameterized using these objects Each channel can be freely parameterized The initial value for the objects is 0 or false The module does not remanently save the parameter values To automatically apply the settings required upon each bus start set the values in the start parameters of the engi neering Index hex Object name Data type Access Unit Description ...

Страница 5: ...mpact representation Word 1 INT IN Channel 1 Value Word 2 INT IN Channel 2 Value Word 3 INT IN Channel 3 Value Word 4 INT IN Channel 4 Value Word 5 Byte 1 Byte 2 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 5 Bit 6 7 Bit 2 Bit 3 Bit 4 5 Bit 6 7 IN IN IN IN IN IN IN IN IN IN IN IN Periphery voltage ok Error Channel 1 Wire break Channel 1 Overrange Channel 1 Limit 1 Channel 1 Limit 2 Channel 2 Wire break Channel 2...

Страница 6: ...or peripheral voltage error RD RD RD RD RD RD RD RD RD RD Communication or configura tion error RD RD RD RD RD Table 3 Module status LED diagnostic and device status 8 5 Channel status LED Each input channel of the module is provided via a channel status LED at the plug Refer to Chapter 3 2 Clamping point assignment on page 1 Meaning of the channel LED LED Meaning Red Signal error Overrange or und...

Страница 7: ...vide the following minimum distances for sufficient cooling 35 mm 0 mm 0 mm 35 mm 35 mm Fig 10 Ventilation distance Additionally provide sufficient distance for mounting dis mounting plugs and cables If more devices are connected in series to the station on the left or right the surface temperature may not exceed 60 C In case of a several line design the supply air has to be measured under each li...

Страница 8: ... to be met Use only insulated copper wires suitable for at least 60 C 9 7 Dismounting module For dismounting use a common tool such as a slotted screwdriver with a 2 5 mm blade NOTICE Destruction of components and devices due to mounting and dismounting under voltage Disconnect the module and all connected module compo nents from voltage before mounting or dismounting Removing module from support ...

Отзывы: