3. Control cabinet PC and multi-touch display with a voltage supply of 24 V
DC
4. Video and USB connection set up:
●
CDI+ connection (RKB008)
or
●
Displayport cable und USB cable (RKB0063/RKB0019)
11.2 Commissioning video and multi-touch operation
11.2.1 Single display DE either at the control cabinet PC PR31 or PR4x
CDI+
max. 100 m
XETH
XETH
Fig. 11-1: Connection via the long distance interface CDI+
After switching on the control cabinet PC and the DE display, the display detects
the CDI+ connection and "RX" is shown in the lower left corner of the display.
The DE device in the On-Screen menu is provided with the standard setting CDI+
connection ("Input rx"). Thus, the video output and the multi-touch operation
are available immediately after the initial start.
Displayport
XUSB
XUSB
XDP
XDP
USB
Fig. 11-2: Connection via standard interface
After switching on the control cabinet PC and the DE display, the display detects
the Displayport connection and "DP" is shown in the lower left corner of the dis-
play. To ensure a proper function of the video and USB connection, set the video
input via the On-Screen menu on the Displayport ("Input DP").
"Home" key
●
Open On-Screen menu
●
Confirm selected menu item
"i" key
●
Navigate in the menu
32/45
Commissioning
ctrlX HMI DE0015, DE0021 Multi-Touch
Displays (Housing Devices)
Bosch Rexroth AG R911405731_Edition 02