The maximum current carrying capacity is 500 mA per USB port.
9.4 USB interfaces XUSBIN
If a display is connected via the display port (XDP) or via HDMI (XHDMI), the
USB signals of the touch and the connected USB devices have to be connected
to the control cabinet PC via XUSBIN.
When using XCDI+rx, these USB signals of the touch and the connected USB de-
vices are also transferred. A separate connection to the control cabinet PC via
XUSBIN is not required.
9.5 Display port XDP
The display port XDP interface connects the operator display DR to the display
port interface of a control cabinet PC.
9.6 Long distance XCDI+rx
The long distance XCDI+rx interface connects the operator display DR to the
long distance XCDI+tx interface of a control cabinet PC.
9.7 XHDMI
The HDMI interface connects the operator display DE to the HDMI interface of a
control cabinet PC.
ctrlX HMI DE0015, DE0021 Multi-Touch
Displays (Housing Devices)
15/45
Interfaces
R911405731_Edition 02 Bosch Rexroth AG