21 / 50
ctrlX CORE X7
Interface description
Bosch Rexroth AG
R911419122, Edition 01
Table 7: Module-specific CoE objects
Index (hex)
Object name
Data type
Error, warning
Diagnostic
number
Unit
6000
U
P
Supply periphery
6000:01
U
P
Voltage
Uint16
‒
‒
mV
6000:02
U
P
Current
Uint16
‒
‒
mA
6010
U
P
Supply logic
6010:01
U
L
Voltage
Uint16
‒
‒
mV
6010:02
U
L
Current
Uint16
‒
‒
mA
6020
State
6020:01
U
P
Undervoltage Bit
W
0x3420
‒
6020:02
U
P
Overvoltage
Bit
W
0x3410
‒
6020:03
U
P
Overcurrent
Bit
E
0x2316
‒
6020:04
U
L
Undervoltage Bit
W
0x3421
‒
6020:05
U
L
Overvoltage
Bit
W
0x3411
‒
6020:06
U
L
Overcurrent
Bit
E
0x2315
‒
8000
System info
8000:01
Temperature
Int16
W
0x4210
0x4220
0.1 °C
8000:02
Power logic used Uint16
‒
‒
mW
8000:03
Power logic avail-
able
Uint16
‒
‒
mW
A000:0
Material number String(20)
‒
‒
‒
A010:0
Full serial number String(20)
‒
‒
‒
Int
er
faces