Safety instructions
DANGER
High voltage!
Danger to life, risk of injury due to electric shock, or risk of serious injury!
Before using the system or starting service/maintenance work, make sure you have
read and understood these operating instructions.
Only those trained and qualified to work with or on electrical equipment are permitted
to operate, maintain and repair this equipment.
Follow general construction and safety regulations for working on electrical power in-
stallations.
Before the device is switched on, the grounding conductor must have been perma-
nently connected to all electrical equipment in accordance with the connection dia-
gram.
Do not operate electrical equipment at any time, even for brief measurements or tests,
if the device grounding conductor is not permanently connected to the mounting
points of the components provided for this purpose.
Disconnect the device from the power supply or voltage source before accessing
electrical parts with voltages greater than 50 V. Protect it against being switched on
again.
After switching off the power supply, wait 10 seconds for the system to discharge be-
fore opening the housing or starting repair/maintenance work.
For electrical drive and filter components:
After switching off, take the specified discharging time for the respective components
into account before accessing the devices. Measure the voltage in the capacitors be-
fore beginning work to preclude any hazard if the device is touched.
Do not touch the electrical connection points of the components while the device is
switched on.
European countries: corresponding to EN 50178/1998, paragraph 5.3.2.3.
USA: See National Electric Code (NEC), National Electric Manufacturers Association
(NEMA) and any regional building codes.
The user must comply with all the above points at all times.