Settings Customer level
Rego 1000 – 6 721 831 662 (2021/03) en
9
▶ For description of setting of
Extra hot water
(
Chapter 6.3,
2.3
Extra hot water
).
Party
Party mode means that a running room program is stopped during the
set time in order to avoid a temperature drop.
>Number of hours
▶ Select the number of hours that party mode should be active for.
The function starts immediately on all activated circuits.
>Circuit x
▶ Select
Yes
to enable party mode.
Party mode can be enabled for each installed circuit. The menu is
displayed only if more than one circuit is installed.
>Deactivate party mode
▶ Select
Yes
to disable party mode on all activated circuits.
The heat pump returns to program mode.
The menu is displayed only if party mode is active.
Holiday
▶ For description of setting of
Holiday
(
Chapter 6.3,
3
Holiday
).
Disable cooling
The menu is displayed only if the cooling function is installed and affects
all circuits with cooling.
6.2
Room temperature
Press the
button in the Initial menu to move to the top menu level.
Select
1
Room temperature
to adjust the heating.
Under
1
Room temperature
there is:
•
1.1 Circuit 1 Heating
•
1.3/1.4
Circuit 2, 3...
(option)
•
1.10 General
1.1 Circuit 1 Heating
1.1.5 Heat curve
The heat curve constitutes the basis for the control unit's control of the
temperature on the heating water to the circuit and indicates how high it
needs to be in relation to the outdoor temperature. The control unit
increases the temperature of the heating water when the outdoor
temperature drops. The temperature of the heating water out to the
circuit, i.e. the flow temperature is measured by sensor T1 for circuit 1
(full name E11.T1) and sensor T1 for circuit 2 (full name E12.T1).
Each circuit is controlled by its own heat curve. The installer sets the
type of heating for each circuit, that is
Radiator
or
Underfloor
. The heat
curve for
Underfloor
has lower values because the floors do not tolerate
such high temperatures.
Fig. 17 Radiator
The figure indicates the factory setting curve for a radiator circuit. At -
2.5 °C the flow set point is 37.4 °C.
Fig. 18 Underfloor
The figure indicates the factory setting curve for an underfloor circuit. At
-2.5 °C the flow set point is 27.2 °C.
Setting of heat curve
A heat curve is set for each circuit. If the room temperature is perceived
to be too high or too low in the circuit, it is preferable to adjust the curve.
The curve can be changed in different ways. The slope of the curve can
be changed by offsetting the flow temperature upwards or downwards
on the left-hand side (the value at outdoor temperature 20 °C, factory
value 22.0 °C) as well as the right-hand side (the value at outdoor
After a period with blocked hot water production, e.g.,
holiday, it is recommended to enable the extra hot water
function so as to eliminate bacteria and quickly reach the
correct hot water temperature.
Factory setting
0h
Lowest value
0h
Highest value
99h
Table 4 Party duration
Factory setting
No
Alternative
No/Yes
Table 5 Enable party mode
Factory setting
No
Alternative
No/Yes
Table 6 Deactivate party mode
It takes a long time before the cooling mode manages to
affect the temperature in the house, therefore wait at
least one day after disabling/enabling before making any
additional adjustments.
If the heat curve has been set too high, the display will
show the message
Too high heat curve setting
.
▶ Change the heat curve setting.
6 720 614 789-15.3I
T1(˚C)
T2(˚C)
20
15
10
5
0
-5
-10
-15
-20
-25
-30
-35
80
70
60
50
40
30
20
10
6 720 614 789-16.3I
T1(˚C)
T2(˚C)
20
15
10
5
0
-5
-10
-15
-20
-25
-30
-35
80
70
60
50
40
30
20
10
Содержание Rego 1000
Страница 1: ...User Guide Rego 1000 mode info menu ok 6 721 831 662 2021 03 en ...
Страница 21: ...Rego 1000 6 721 831 662 2021 03 en 21 Notes ...
Страница 22: ...Rego 1000 6 721 831 662 2021 03 en 22 Notes ...
Страница 23: ...Rego 1000 6 721 831 662 2021 03 en 23 Notes ...
Страница 24: ......