Settings Customer level

Rego 1000 – 6 721 831 662 (2021/03) en

9

▶ For description of setting of  

Extra hot water

 

(

Chapter 6.3, 

2.3 

 

Extra hot water

 ).

Party

Party mode means that a running room program is stopped during the 
set time in order to avoid a temperature drop.

>Number of hours

▶ Select the number of hours that party mode should be active for.

The function starts immediately on all activated circuits.

>Circuit x

▶ Select 

Yes

 to enable party mode.

Party mode can be enabled for each installed circuit. The menu is 
displayed only if more than one circuit is installed.

>Deactivate party mode

▶ Select 

Yes

 to disable party mode on all activated circuits.

The heat pump returns to program mode.
The menu is displayed only if party mode is active.

Holiday

▶ For description of setting of 

Holiday

 

(

Chapter 6.3, 

 

Holiday

 ).

Disable cooling

The menu is displayed only if the cooling function is installed and affects 
all circuits with cooling.

6.2

Room temperature

Press the 

 button in the Initial menu to move to the top menu level. 

Select 

1

 

Room temperature

  to adjust the heating.

Under 

1

 

Room temperature

  there is:

1.1 Circuit 1 Heating

1.3/1.4 

 

Circuit 2, 3...

  (option)

1.10 General

1.1 Circuit 1 Heating

1.1.5 Heat curve

The heat curve constitutes the basis for the control unit's control of the 
temperature on the heating water to the circuit and indicates how high it 
needs to be in relation to the outdoor temperature. The control unit 
increases the temperature of the heating water when the outdoor 

temperature drops. The temperature of the heating water out to the 
circuit, i.e. the flow temperature is measured by sensor T1 for circuit 1 
(full name E11.T1) and sensor T1 for circuit 2 (full name E12.T1).

Each circuit is controlled by its own heat curve. The installer sets the 
type of heating for each circuit, that is 

Radiator

 or 

Underfloor

. The heat 

curve for 

Underfloor

 has lower values because the floors do not tolerate 

such high temperatures.

Fig. 17 Radiator

The figure indicates the factory setting curve for a radiator circuit. At -
2.5 °C the flow set point is 37.4 °C.

Fig. 18 Underfloor

The figure indicates the factory setting curve for an underfloor circuit. At 
-2.5 °C the flow set point is 27.2 °C.

Setting of heat curve

A heat curve is set for each circuit. If the room temperature is perceived 
to be too high or too low in the circuit, it is preferable to adjust the curve.

The curve can be changed in different ways. The slope of the curve can 
be changed by offsetting the flow temperature upwards or downwards 
on the left-hand side (the value at outdoor temperature 20 °C, factory 
value 22.0 °C) as well as the right-hand side (the value at outdoor 

After a period with blocked hot water production, e.g., 
holiday, it is recommended to enable the extra hot water 
function so as to eliminate bacteria and quickly reach the 
correct hot water temperature.

Factory setting

0h

Lowest value

0h

Highest value

99h

Table 4 Party duration

Factory setting

No

Alternative

No/Yes

Table 5 Enable party mode

Factory setting

No

Alternative

No/Yes

Table 6 Deactivate party mode

It takes a long time before the cooling mode manages to 
affect the temperature in the house, therefore wait at 
least one day after disabling/enabling before making any 
additional adjustments.

If the heat curve has been set too high, the display will 
show the message 

Too high heat curve setting

.

▶ Change the heat curve setting.

6 720 614 789-15.3I

T1(˚C)

T2(˚C)

20

15

10

5

0

-5

-10

-15

-20

-25

-30

-35

80

70

60

50

40

30

20

10

6 720 614 789-16.3I

T1(˚C)

T2(˚C)

20

15

10

5

0

-5

-10

-15

-20

-25

-30

-35

80

70

60

50

40

30

20

10

Содержание Rego 1000

Страница 1: ...User Guide Rego 1000 mode info menu ok 6 721 831 662 2021 03 en ...

Страница 2: ...n in the menu display 5 4 Information from the heat pump 5 4 1 Operating information 5 4 2 Info button 6 4 3 Operating symbols 6 5 Menu overview 7 6 Settings Customer level 8 6 1 Mode button functions 8 6 2 Room temperature 9 6 3 Hot water 12 6 4 Holiday 13 6 5 Energy measurements 13 6 6 Timers 13 6 7 External control 13 6 8 General 13 6 9 Alarms 13 6 10 Access level 14 6 11 Return to factory sett...

Страница 3: ...on in savings Only use original spare parts Service and maintenance must be carried out annually by an authorised service representative Safety of electrical devices for domestic use and similar purposes The following requirements apply in accordance with EN 60335 1 in order to prevent hazards from occurring when using electrical appliances This appliance can be used bychildren of 8 years and olde...

Страница 4: ... version etc 3 Menu navigation 3 1 Initial menu Initial menu shows different temperatures time as well as current operating symbols The window displays information alternately Room temperature if room sensors exist and Flow temperature for each circuit installed Fig 2 Initial menu 1 Outdoor temperature 2 Current operating symbols 3 The circuit room temperature 4 Current time 5 Hot water temperatur...

Страница 5: ...how that the next level is a setting window 5 The function is marked 6 Three of the functions under Hot water Fig 12 Help information 2 1 Graphic display of the value 2 Highest possible value 3 Unit 4 Previous value 5 New value Saved when the menu dial is pressed 6 Lowest possible value Fig 13 Help information 3 1 Option 4 out of 9 is displayed 4 Information from the heat pump The heat pump provid...

Страница 6: ...mponents for which there is a need or which are in operation are displayed in the bottom right corner oftheInitialmenu Theoperatingsymbolsdisplayedcanvarydepending on the type of heat pump Fig 16 Operating symbols 1 Compressor 2 Alarm compressor additional heat 3 Heating 4 Electric additional heat 5 Energy supply cut off 6 Hot water 7 Extra hot water 8 Hot water peak 9 Pool option 10 Cooling optio...

Страница 7: ...1 1 11 8 Copy to all heating circuits No No Yes 1 3 Circuit 2 option 1 3 5 Heat curve see 1 1 5 1 3 7 Room sensor see 1 1 10 1 3 8 Room temperature program see 1 1 11 1 4 Circuit 3 option see 1 3 1 5 Circuit 4 option see 1 3 1 10 General 1 10 1 Summer winter operation 1 10 1 1 Winter operation Automatic On Automatic Off 1 10 1 2 Outdoor temperature limit for change over 18 C 5 C 35 C 2 Hot water 2...

Страница 8: ...ing at tripped underfloor temperature limiter No No Yes 8 5 3 Block heating No No Yes 8 5 6 Room temperature No 0 0 C 10 0 C 35 0 C 8 6 External input circuit 3 option see 8 5 8 7 External input circuit 4 option see 8 5 12 General 12 1 Room sensor settings 12 1 1 Show outdoor temperature in room sensor No No Yes 12 2 Set date yyyy mm dd 12 3 Set time hh mm ss 12 4 Summer winter time Automatic Manu...

Страница 9: ...or T1 for circuit 2 full name E12 T1 Each circuit is controlled by its own heat curve The installer sets the typeofheatingforeachcircuit thatisRadiatororUnderfloor Theheat curveforUnderfloorhaslowervaluesbecausethefloorsdonottolerate such high temperatures Fig 17 Radiator The figure indicates the factory setting curve for a radiator circuit At 2 5 C the flow set point is 37 4 C Fig 18 Underfloor T...

Страница 10: ... leave the curve setting window and return to the menu 1 1 6 Compressor 1 operating time on off Select how long the compressor should be on or off in heating mode Higher set values result in fewer compressor starts and stops which achieves higher economy However more pronounced temperature fluctuations in the heating system may result than with lower values 1 1 7 Compressor 2 operating time on off...

Страница 11: ... Use this function to adjust the room temperature so that the normal room temperature see the previous menu becomes the desired temperature Use this function to simply increase or decrease the heat when there are no room sensors Results in approx 1 C lower room temperature results in approx 0 5 C lower room temperature results in approx 0 5 C higher room temperature results in approx 1 C higher ro...

Страница 12: ...ghtly lower temperature Change to Comfort If more or hotter hot water is desired Thissettingmustbeusedifelectricadditionalheatismissingorifthe hot water circulation is used when the temperature in the hot water circulation is otherwise too low The factory settings for on and off temperature are approx 8 K C lower in Economy mode compared to Comfort mode These values can be adjusted by the installe...

Страница 13: ...ock heating at tripped underfloor temperature limiter 8 1 1 13 Block heating 8 1 1 14 Room temperature Set the room temperature that should apply in the event of enabled external control Value 0 C enables the function The highest temperature is used if temperature changes have been set for a certain circuit at several external inputs 8 1 1 15 Block hot water production 8 1 2 External input 2 Set t...

Страница 14: ...olunitisusedtoshowON OFFstatusforthe heatpumpbutalsotoshowpossiblealarms Thestatuslampistherefore also called alarm lamp Intheeventofanalarmthealarmlampflashesred controlunit untilthe warning cause has disappeared The alarm lamp is not used for warning alarms The room sensor alarm lamp can be blocked The room sensor display is used to indicate alarms for some alarm categories 10 The display window...

Страница 15: ...gory A Alarm lamp buzzer Yes Restart Acknowledgement is required Contact the dealer if the alarm remains active for more than three hours or recurs often 7 7 2 Tripped low pressure switch E2x RLP Function Compressor stops Activated when the pressure in the refrigerant circuit of the heat pump becomes too low Alarm timer starts Yes Reset condition The pressure goes back to the permitted level Categ...

Страница 16: ...ailure on sensor E2x T6 hot gas Function The compressor stops because the hot gas cut out cannot be guaranteed Activated when the sensor s value indicates a temperature lower than 50 C Alarm timer starts Yes Reset condition The value of the sensor indicates 50 C Category E Alarm lamp buzzer Yes Restart Automatic once the alarm cause has disappeared Contact the dealer if the alarm remains active fo...

Страница 17: ...ent is required Contact the dealer 7 7 19 Failure on sensor E11 T1 flow Function The system switches over to control based on sensor T8 The alarmisactivatedwhenthesensor svalueindicatesatemperaturelower than 0 C Reset condition The value of the sensor indicates 0 C Category H Alarm lamp buzzer Yes Restart Automatic once the alarm cause has disappeared Contact the dealer if the alarm remains active...

Страница 18: ... recurs often 7 7 29 Failure on sensor E31 TT T5 room Function The alarm is activated when the sensor s value indicates a temperature lower than 1 C In the event of a failure on sensor T5 the room temperature influence is set to 0 Reset condition The value of the sensor indicates 1 C Category H Alarm lamp buzzer Yes Restart Automatic once the alarm cause has disappeared 7 7 30 Short circuit on sen...

Страница 19: ...at transfer fluid out and heat transfer fluid in becomes too high Reset condition The warning is deactivated on acknowledgement of the warning display Category L Alarm lamp buzzer No Restart The warning does not close anything but is registered in the alarm log Check and clean the particle filter if required Contact the dealer if the warning remains after acknowledgement 7 8 3 High temperature dif...

Страница 20: ... condition The temperature of the collector circuit exceeds the lowest permitted temperature Category J that can be transformed into A 7 9 6 Hot water peak failure new try within 24 hours Function The hot water has not come up at the right temperature The hot water peak is repeated at the same time on the next day Reset condition The correct hot water peak temperature is reached Category Z 7 9 7 T...

Страница 21: ...Rego 1000 6 721 831 662 2021 03 en 21 Notes ...

Страница 22: ...Rego 1000 6 721 831 662 2021 03 en 22 Notes ...

Страница 23: ...Rego 1000 6 721 831 662 2021 03 en 23 Notes ...

Страница 24: ......

Отзывы: