The transformers mentioned above are Primary Rated 120VAC, 60 Hz, 0.48 Amps, Secondary
16.5VAC, 40VA.
When selecting a suitable 18VAC Class 2 plug-in transformer, the following transformers are
suggested:
–
TDC Part No DA-22-18, Primary Rated 120VAC, 60 Hz, 30VA, Secondary Rated 18VAC, 1.3
Amps, 22VA.
Notice!
For UL installations when transformer is used, restraining tab is to be connected.
Notice!
For UL installations when a repeater is installed, a minimum of two repeaters must be
installed for proper signal routing.
Information related to the internal standby battery is as follows:
–
Power/voltage (Standby Battery): Rated 3.7 VDC, 3050mAH, EVE ENERGY CO Part No
P0046-LF (Not user replaceable)
Notice!
For standby battery to be operative, the tamper switch is required to be engaged.
Standby battery is capable of providing 72 hours of standby power to the RF repeater for a UL
Burglar Alarm Installation (Bank Safe and Vault).
–
24 Hours for Household Fire Warning Systems
–
8 Hours for HOLD UP Burglar Alarms
–
4 Hours for Burglar Alarm Mercantile Installations
RADION glassbreak
Notice!
The RFGB-A has not been investigated by UL, and not part of a UL Listed system.
RADION TriTech
Notice!
Pet Immunity has not been evaluated by UL.
Notice!
Draft and Insect Immunity has not been evaluated by UL.
12
en | RADION receiver SD
RADION receiver SD
2014.03 | 06 | F.01U.261.834
Reference Guide
Bosch Security Systems, Inc.