CONTROL OUT HP
The lower half of the control port has six freely programmable high power (HP) control
outputs numbered 1 through 6. In inactive mode (Off), these control outputs are open, while
in active mode (On), they are closed to ground. To operate the externally connected elements,
a voltage source is available on the connection V; see also the following diagram.
Notice!
The voltage value used as the supply voltage for the controller is always present on the V
output.
!
Caution!
The maximum permissible power on the V output is 200 mA.
Figure 6.14: Sample application of a high power control output (LED with series resistor)
6.11.2
34
en | Connection
PAVIRO Controller
08-May-2017 | 04 | F01U306900
Operation manual