– Insert the accessories into the holders provided for them:
Suction tubes
(33)
into the holders
(20)
, crevice
nozzle
(29)
into the holder
(21)
, floor nozzle
(32)
into
the holder
(22)
.
– Open the elastic bands of the vacuum hose holder
(4)
and wrap the vacuum hose
(25)
around the top part of
the dust extractor in the holder
(4)
.
Hook the elastic bands back in.
– Only ever carry the dust extractor by the carrying
handle
(10)
.
– Store the dust extractor in a dry room and secure it so
that it cannot be used by unauthorised persons.
– Put the castor brake
(15)
down to hold the castors
(16)
in place.
Rectifying faults
u
If a fault (e.g. a filter damage) occurs, the vacuum
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Warning! The dust extractor contains dust particles that pose a risk to health.
Observe all the safety warnings in these in-
structions.
Problem
Corrective measures
Suction turbine will not switch on.
– Check the mains cable, mains plug, fuse, socket and fill level sensors
(40)
.
The mode selector switch
(7)
is set to "automatic start/stop".
– Set the mode selector switch
(7)
to the "vacuuming" symbol or switch on the
power tool plugged into the plug socket
(5)
.
The suction turbine switches off.
– Empty the container
(1)
.
The suction turbine will not switch on
again after the container has been
emptied.
– Switch the dust extractor off and wait five seconds before switching it back on.
– Clean the fill level sensors
(40)
and the space between the fill level sensors
(40)
using a brush.
The suction power is decreasing.
– Remove any blockages from the vacuum nozzle, suction tube
(33)
, vacuum hose
(25)
or flat-pleated filter
(28)
.
– Change the disposal bag
(27)
or safety filter bag
(26)
.
– Make sure the filter cover
(39)
is engaged correctly.
– Place the top part of the dust extractor
(12)
on correctly and close the catches
(13)
.
– Change the flat-pleated filter
(28)
.
Dust is escaping during extraction
– Check that the flat-pleated filter
(28)
has been fitted correctly.
– Change the flat-pleated filter
(28)
.
Automatic switch-off (wet extraction)
is not working.
– Clean the fill level sensors
(40)
and the space between the fill level sensors
(40)
using a brush.
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
– Check the fill level regularly.
Acoustic warning signal sounds.
Suction power setting too low.
– Set the suction power regulator
(8)
to a higher setting.
Hose diameter setting is wrong.
– Set the volume flow controller
(6)
to the correct vacuum hose diameter.
Vacuum hose
(25)
is blocked or twisted.
– Remove blockage or untwist hose.
Disposal bag/safety filter bag full.
– Change the disposal bag
(27)
or safety filter bag
(26)
.
Flat-pleated filter
(28)
is dirty.
– Clean or change the flat-pleated filter if required.
The airflow supplied by the connected power tool is insufficient.
Bosch Power Tools
1 609 92A 71M | (01.12.2021)
Содержание Professional Heavy Duty GAS 35 H AFC
Страница 4: ...4 25 29 24 28 27 5 m 31 30 23 33 32 23 24 25 26 1 609 92A 71M 01 12 2021 Bosch Power Tools ...
Страница 7: ... 7 I2 J K 28 40 24 40 29 33 22 21 20 32 17 Bosch Power Tools 1 609 92A 71M 01 12 2021 ...
Страница 308: ...308 1 609 92A 71M 01 12 2021 Bosch Power Tools ...
Страница 312: ...IV 1 609 92A 71M 01 12 2021 Bosch Power Tools ...