– Voltage-free conductors can be detected as metal objects in the operation
mode
“Metal”
. This does not apply for stranded conductors (contrary to solid
conductors or cable).
– Static electricity can lead to inaccurate indication of electric lines, e.g., over
a large range. To improve the indication, place your free hand flat on the wall
next to the measuring tool, in order to remove the static electricity.
Working Advice
f
Measuring values can be impaired through certain ambient conditions.
These include, e.g., the proximity of other equipment that produce
strong magnetic or electromagnetic fields, moisture, metallic building
materials, foil-laminated insulation materials or conductive wallpaper or
tiles.
Therefore, please also observe other information sources (e.g. con-
struction plans) before drilling, sawing or routing into walls, ceilings or floors.
Marking Objects
If required, detected objects can be marked. Perform a measurement as usual.
Once you have found the boundaries or the centre of an object, mark the sought
location through the marking hole
8
.
Temperature Control
The measuring tool is equipped with a temperature control indicator, as accurate
measurements are only possible as long as the temperature within the measur-
ing tool remains constant.
When the temperature control indicator
d
lights up, the measuring tool is not
within the operating temperature range or was subject to large variations in tem-
perature.
Switch the measuring tool off and allow it to adjust to the ambient
temperature before switching it on again.
Warning Function
When indicator
b
lights up on the display, the measurement must be restarted.
Remove the measuring tool from the wall and place it on the base material at a
different location.
When indicator
b
flashes on display
7
, send the measuring tool in the provided
protective pouch to an authorised customer services agent.
Recalibration
When measuring indicator
f
indicates a continuously high amplitude in the oper-
ating mode
“Metal”
, even though there is no metal object near the measuring
tool, the measuring tool can be manually recalibrated.
– Switch the measuring tool off.
– Remove all objects near the measuring tool that could be detected, including
your wrist watch or rings made of metal, and hold the measuring tool up.
Pay attention that battery indicator
e
indicates at least 1/3 capacity:
Hold the measuring tool in such a manner that the type plate
12
faces toward
the ground. Avoid bright light sources or direct sunlight from shining on the
area
11
and
12
, without covering off this area.
– Press and hold buttons
5
and
4
until the illuminated ring
9
lights up red. Then
release both buttons.
– When the calibration was successful, the measuring tool will automatically
start after a few seconds, and will be ready for operation again.
Note:
If the measuring tool does not automatically start, repeat the recalibration.
If the measuring tool still does not start, send it in the provided protective pouch
to an authorised customer services agent.