18
| English
1 609 92A 0JX | (28.3.14)
Bosch Power Tools
e
Previous measuring value
f
Unit of measure
g
Current measuring value
Technical Data
Digital Laser Measure
PLR 15
Article number
3 603 F72 000
Measuring range (typical)
0.15 –15 m
A)
Measuring accuracy (typical)
±3.0 mm
B)
Lowest indication unit
1 mm
Measuring duration
– typical
– maximal
0.5 s
4 s
Operating temperature
– 10 °C ... +40 °C
Storage temperature
– 20 °C ... +70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
Laser beam diameter (at 25 °C) and at 10 m
distance, approx.
9 mm
Batteries
2 x 1.5 V LR03 (AAA)
Battery service life in measuring operation, ap-
prox.
5 h
Weight according to EPTA-Procedure
01/2003
0.1 kg
Dimensions
100 x 36 x 23 mm
A) The working range increases depending on how well the laser light is reflected from
the surface of the target (scattered, not reflective) and with increasedbrightness of
the laser point to the ambient light intensity (interior spaces, twilight). In unfavourable
conditions, e.g., with extreme interior illumination or a badly reflecting surface, the
measuring range may be limited.
B) In unfavourable conditions, e.g., with extreme interior illumination, badly reflecting
surface or the room temperature deviating heavily from 25 °C, the maximum devia-
tion can be up to ±7 mm per 15 m. In favourable conditions, a deviation influence of
±0,05 mm/m must be taken into account.
The measuring tool can be clearly identified with the serial number
6
on the type plate.
OBJ_BUCH-1900-002.book Page 18 Friday, March 28, 2014 3:24 PM