WFMC Service Tips
WFMC Service Tips
--
--
Test Program (2C): Motor Control
Test Program (2C): Motor Control
Fault Codes (Test 1)
Fault Codes (Test 1)
63
Test
P1:ERRORS
/
P:01
(Viewing motor control fault codes) --
Start & end test
P1
by
pushing
Start/Pause
button. Scroll through list of (18) fault codes by pushing
Spin Selection
(WFMC3200) or
Menu
(WFMC6400) buttons.
•
WFMC3200 display alternates between fault code (e.g.
d:01
) & when fault occurred on in last 16
washes (e.g.
C:00
) – shows
C:00
if fault didn’t occur.
•
WFMC6400 display shows fault code & when fault occurred on in last 16 washes (e.g.
0 - dr:01
).
Last 16 fault codes are
stored & displayed!
HINT: # of faults reads “
0
”
for faults which didn’t occur.
Look at # of faults, not error
#, to see if faults occurred --
scroll thru all faults to check
if any occurred.
WFMC32
Display
WFMC64
Display
Test #
Problem
Possible Cause(s)
d:01
dr:01
P:04
Motor control short circuit
Faulty motor control.
d:02
dr:02
P:04
Motor control interruption
Faulty motor control.
d:03
dr:03
P:04
Damaged motor control temperature sensor Faulty temperature sensor.
d:06
dr:06
P:04
NTC relay failure
NTC too hot or relay stuck closed.
d:07
dr:07
P:04
Motor winding short circuited
Motor winding short circuited
d:08
dr:08
P:04
Motor speed sensor failed
Faulty speed sensor or wire harness.
d:09
dr:09
P:04
Voltage too high
Faulty motor control.
d:10
dr:10
P:04
Power limiter switch off
Motor overloaded or binding.
d:11
dr:11
P:04
Voltage too low
Faulty motor control.
d:12
dr:12
P:04
Motor control high current switch off
Motor overloaded or binding.
d:13
dr:13
P:04
Motor control high temperature switch off
Motor overloaded or binding.
d:14
dr:14
P:04
Motor control high temperature warning
Motor overloaded or binding.
d:15
dr:15
P:04
Power limiter warning
Motor overloaded or binding.
d:16
dr:16
P:04
Motor high temperature switch off
Motor overloaded or binding.
d:17
dr:17
P:04
Motor high temperature warning
Motor overloaded or binding.
d:18
dr:18
P:04
Peak voltage too high
Faulty motor control.