Alarm and relay connector
Figure 5.3
Alarm and relay connector pins
–
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
–
Alarm output relay switching capability: Max voltage 30VAC
or +40 VDC. Max 0.5 A continuous, 10 VA.
–
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled
with 22 kOhm pull-up to +3.3 V.
–
Alarm in: configurable as active low or active high.
–
Max. 42 V allowed between camera ground and each of the
relay pins.
Use the alarm input to connect external alarm devices such as
door contacts or sensors. A zero potential make-contact or
switch can be used as the actuator (use a bounce-free contact
system).
Use the alarm relay output for switching external devices such
as lamps or sirens.
Pin
Alarm socket
1
Alarm in 1
2
Alarm in 2
3
Relay out contact 1
4
Ground
5
Ground
6
Relay out contact 2
Alarm
1
2
3
4
5
6
5 mm
(0.2 in)