background image

MIC-WKTI and MIC-WKT-IR Installation Manual                           

  

 

                                            

                              

EN | 9                   

 
 
Bosch Security Systems 

Issue 1 

 

 
 

Installation of the 705-200 Washer Pump Drive Card

 

 

 

 

Installation of the 705-200 Washer Pump Drive Card is best performed prior to 
installing the Power Supply in the field. To install the 705-200 Washer Pump 
Drive Card, please do the following:- 
 
1.

 

The power supply unit must be switched off and unplugged prior to 
carrying out any work. 

 
2.

 

Ensure that the four (4) card spacer supports fitted in the power supply are 
positioned in the left and right most mounting holes on the power supply 
printed circuit board, so that the MIC-WSH card is supported in each 
corner. 

 
3.

 

Should you need to reposition the card spacers first remove the four (4) 
screws holding the power supply PCB to the enclosure, turn the PCB over 
and remove the two (2) card spacer supports, these spacers should be re-
fixed at the correct positions shown as A and B on Figure 1 below. 
 

4.

 

Insert the 705-200 Washer Pump Drive Card so that the connector 
labelled CN1 as shown on Figure 2 below plugs into the CN1 header on 
the Power Supply labelled C on Figure 1. Then fix to the card spacer 
supports using M3x6 screws. 
 

5.

 

The 705-200 Washer Pump Drive Card is now ready to accept third party 
washer pump electrical connections. Please see 

Installation of the

 

Washer Pump 

for more details. 

 
 
 
 

 

 
Figure 1:- MIC400 Non-IR Power Supply PCB Layout 

 

A. Right hand - Add on 

card support spacers & 

holes

B. Centre – Add on 

card support spacers & 

holes

C. Connection 

Header CN1

 

Figure 2:- 705-200 Washer Pump Drive Card PCB Layout 

 

 

 

CAUTION

: Electrical Danger: Ensure all power is disconnected 

before opening or working upon the MIC400 Power Supply Unit. 
Installation must be carried out by suitably qualified persons & 
all local safety regulations should be followed.

Содержание MIC-WKT

Страница 1: ...Bosch Security Systems MIC WKT and MIC WKT IR Installation Manual EN Installation and Operation Manual ...

Страница 2: ...ystems Issue 1 MIC WKT and MIC WKT IR Washer Pump Drive Card Kits for the MIC400 Camera Power Supply Units Installation and Operation Manual Chapters_______________________________________________ 1 Introduction 2 Installation Instructions 3 Technical Specifications ...

Страница 3: ...1 Introduction 1 7 Versions 1 7 Features 1 7 Unpacking 1 8 Packaging Contents 1 8 Installation 2 9 705 200 Washer Pump Drive Card Functionality 2 9 Installation 2 9 Connecting the washer pump to the IR power supply 2 11 Technical Specifications 3 13 Technical Specifications 3 13 ...

Страница 4: ...is product yourself please contact Bosch Security Systems for assistance 14 Only use approved attachments or accessories specified by the manufacturer Any changes or modifications made to the equipment not expressly approved in writing by Bosch Security Systems could prevent proper or safe operation of the product and will invalidate the warranty 15 Please dispose of disused electrical electronic ...

Страница 5: ... Electrical Electronic Equipment 2002 96 EC Reference Glossary of Terms PTZ Pan Tilt Zoom PSU Power Supply Unit IR Infra Red Camset Bosch Security Systems configuration set up software please This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic e...

Страница 6: ...n Manual EN 6 Bosch Security Systems Issue 1 CHAPTER 1 Introduction The MIC WKT and MIC WKT IR Washer Pump Drive Card Kits provide the required fittings to enable third party washer kits to remotely clean the window of the MIC400 camera ...

Страница 7: ...y Systems and will need to be purchased separately to suit the particular installation The 705 200 is a Printed Circuit Board as shown below and plugs directly into Non IR Power Supply Units for the MIC400 PTZ Camera This card is only required for MIC400 Power Supply Units which do not support integrated washer or alarm operations these are the following MIC400 Power Supply Units MIC 240PSU MIC 12...

Страница 8: ...he Washer Nozzle 200 007 200 008 For the MIC WKT IR the following items should be included MIC WKT and MIC WKT IR Washer Kit Installation Manual this Booklet Single Jet Washer Nozzle 5mm Two 2 Brackets for mounting the Washer Nozzle 200 007 200 008 CHAPTER 2 Installation 705 200 Washer Pump Drive Card Functionality The 705 200 Washer Pump Drive Card provides an output relay SK1 rated at 240vAC up ...

Страница 9: ...ver and remove the two 2 card spacer supports these spacers should be re fixed at the correct positions shown as A and B on Figure 1 below 4 Insert the 705 200 Washer Pump Drive Card so that the connector labelled CN1 as shown on Figure 2 below plugs into the CN1 header on the Power Supply labelled C on Figure 1 Then fix to the card spacer supports using M3x6 screws 5 The 705 200 Washer Pump Drive...

Страница 10: ...the washer pump power cable should be protected externally by a suitably rated fuse 7 Connect the washer pump drive power cable to the 705 200 Washer Pump Drive Card using the SK1 terminal the connections required are shown below 8 Secure all external pipe work and cabling fill the reservoir then plug in the MIC400 Power Supply Unit 9 Press the push to test button SW1 to test the pump operation ho...

Страница 11: ...s instructions and all applicable local building codes 3 Connect the 5mm tubing from the pump to the washer nozzle 4 Ensure the MIC400 Power Supply Unit is completely disconnected from the power source 5 Locate the 2 way terminal block HD7 in the bottom left hand corner of the IR power supply as shown on Figure 3 this outputs electrical current at 230VAC or 110VAC ONLY depending upon PSU link sele...

Страница 12: ...nd cabling fill the washer reservoir then plug in the MIC400 Power Supply Unit 9 Press the push to test button SW1 to test the pump operation hold button SW1 down to expel the air from the tubing and prime the pump for operation 10 When the pump is primed close the MIC400 Power Supply Unit 11 Point the MIC400 at the wash nozzle and set the wash wipe position via the control room interface or via a...

Страница 13: ...0096 Fax 1 585 223 9180 Email security sales us bosch com www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securit...

Отзывы: