Connecting a Washer Pump to Infra Red Power Supplies 

 
Bosch Security Systems Infra Red Power supplies have an integrated Washer 
Pump Drive and 4 – Alarm input built into the printed circuit board for the following 
power supplies:- 
 
MIC-IR-240PSU 
MIC-IR-12PSU 
MIC-IR-24PSU 
MIC-IR-115PSU 
 

Figure 3 MIC400IR Power Supply Printed Circuit Board Diagram 

 

 
To connect a washer pump to the IR power supply, please do the following:- 
 
 

 

 

 

 
 

 

 

1.

 

Fit the washer nozzle to the appropriate bracket (wall or corner mount) 
and then fix the washer nozzle bracket to the wall or corner bracket 
using one of the M8 fixing bolts, ensure the washer nozzle points 
towards the camera and does not obstruct the camera view. 

 
2.

 

Fit the washer pump and reservoir in a suitable location taking all 
necessary safety precautions, observing the manufacturers instructions 
and all applicable local building codes.   

 
3.

 

Connect the 5mm tubing from the pump to the washer nozzle. 

 
4.

 

Ensure the MIC400 Power Supply Unit is completely disconnected from 
the power source. 

 

5.

 

Locate the 2 way terminal block HD7 in the bottom left hand corner of 
the IR power supply as shown on 

Figure 3

, this outputs electrical 

current at 230VAC or 110VAC ONLY depending upon PSU link 
selection. 

 

6.

 

Feed the washer pump power cable through one of the weatherproof 
glands in the power supply enclosure, leave sufficient slack to connect 
the cable to HD7. 

CAUTION

: Electrical Danger: Ensure all power is 

disconnected before opening or working upon the MIC400 
Power Supply Unit. 
Installation must be carried out by suitably qualified 
persons & all local safety regulations should be followed. 

CAUTION

: This washer pump drive is suitable for 

230v/110v AC pumps ONLY (HD7 outputs at 230VAC or 
110VAC depending on PSU link selection) if a lower 
voltage pump is desired then an external transformer of a 
suitable type must be used, please refer to suitably 
qualified personnel in this instance.

Содержание MIC-WKT

Страница 1: ...Bosch Security Systems MIC WKT and MIC WKT IR Installation Manual EN Installation and Operation Manual ...

Страница 2: ...ystems Issue 1 MIC WKT and MIC WKT IR Washer Pump Drive Card Kits for the MIC400 Camera Power Supply Units Installation and Operation Manual Chapters_______________________________________________ 1 Introduction 2 Installation Instructions 3 Technical Specifications ...

Страница 3: ...1 Introduction 1 7 Versions 1 7 Features 1 7 Unpacking 1 8 Packaging Contents 1 8 Installation 2 9 705 200 Washer Pump Drive Card Functionality 2 9 Installation 2 9 Connecting the washer pump to the IR power supply 2 11 Technical Specifications 3 13 Technical Specifications 3 13 ...

Страница 4: ...is product yourself please contact Bosch Security Systems for assistance 14 Only use approved attachments or accessories specified by the manufacturer Any changes or modifications made to the equipment not expressly approved in writing by Bosch Security Systems could prevent proper or safe operation of the product and will invalidate the warranty 15 Please dispose of disused electrical electronic ...

Страница 5: ... Electrical Electronic Equipment 2002 96 EC Reference Glossary of Terms PTZ Pan Tilt Zoom PSU Power Supply Unit IR Infra Red Camset Bosch Security Systems configuration set up software please This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic e...

Страница 6: ...n Manual EN 6 Bosch Security Systems Issue 1 CHAPTER 1 Introduction The MIC WKT and MIC WKT IR Washer Pump Drive Card Kits provide the required fittings to enable third party washer kits to remotely clean the window of the MIC400 camera ...

Страница 7: ...y Systems and will need to be purchased separately to suit the particular installation The 705 200 is a Printed Circuit Board as shown below and plugs directly into Non IR Power Supply Units for the MIC400 PTZ Camera This card is only required for MIC400 Power Supply Units which do not support integrated washer or alarm operations these are the following MIC400 Power Supply Units MIC 240PSU MIC 12...

Страница 8: ...he Washer Nozzle 200 007 200 008 For the MIC WKT IR the following items should be included MIC WKT and MIC WKT IR Washer Kit Installation Manual this Booklet Single Jet Washer Nozzle 5mm Two 2 Brackets for mounting the Washer Nozzle 200 007 200 008 CHAPTER 2 Installation 705 200 Washer Pump Drive Card Functionality The 705 200 Washer Pump Drive Card provides an output relay SK1 rated at 240vAC up ...

Страница 9: ...ver and remove the two 2 card spacer supports these spacers should be re fixed at the correct positions shown as A and B on Figure 1 below 4 Insert the 705 200 Washer Pump Drive Card so that the connector labelled CN1 as shown on Figure 2 below plugs into the CN1 header on the Power Supply labelled C on Figure 1 Then fix to the card spacer supports using M3x6 screws 5 The 705 200 Washer Pump Drive...

Страница 10: ...the washer pump power cable should be protected externally by a suitably rated fuse 7 Connect the washer pump drive power cable to the 705 200 Washer Pump Drive Card using the SK1 terminal the connections required are shown below 8 Secure all external pipe work and cabling fill the reservoir then plug in the MIC400 Power Supply Unit 9 Press the push to test button SW1 to test the pump operation ho...

Страница 11: ...s instructions and all applicable local building codes 3 Connect the 5mm tubing from the pump to the washer nozzle 4 Ensure the MIC400 Power Supply Unit is completely disconnected from the power source 5 Locate the 2 way terminal block HD7 in the bottom left hand corner of the IR power supply as shown on Figure 3 this outputs electrical current at 230VAC or 110VAC ONLY depending upon PSU link sele...

Страница 12: ...nd cabling fill the washer reservoir then plug in the MIC400 Power Supply Unit 9 Press the push to test button SW1 to test the pump operation hold button SW1 down to expel the air from the tubing and prime the pump for operation 10 When the pump is primed close the MIC400 Power Supply Unit 11 Point the MIC400 at the wash nozzle and set the wash wipe position via the control room interface or via a...

Страница 13: ...0096 Fax 1 585 223 9180 Email security sales us bosch com www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securit...

Отзывы: