![Bosch MIC Series 550 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/bosch/mic-series-550/mic-series-550_user-manual_40696035.webp)
Notice!
A previously-configured MIC with an address above 32 (Pelco-P upper limit) or 254 (Pelco-D
upper limit) can be used without readdressing the unit. However, no two (2) addresses can
be the same. For example:
Pelco-P addresses above 32 are repeated in multiples of 32 (1, 33, 65, 97 are the same).
Pelco-D addresses above 254 are repeated in multiples of 254 (1, 255, 509, 763 are the
same).
To set FastAddress with a Pelco Keyboard:
1.
Press and hold 95-PRESET for two seconds to open the Pelco Setup menu.
2.
Move the joystick to select the Command Lock menu.
3.
Press the FOCUS or the IRIS button to turn Command Lock to OFF.
4.
Move to the FastAddress menu and press the FOCUS button or the IRIS button to open
the menu.
5.
Use the joystick to enter the unique identifier for the camera.
Move the joystick up or down to select the number.
Move the joystick right to move to the next number position.
6.
Move the joystick right to select Continue. Then, press the FOCUS or the IRIS button.
7.
Use the keyboard to enter the FastAddress number. Then, press the Camera button.
Note: To use a FastAddress number that is already assigned to a different camera, you
must clear the number first.
8.
Move the joystick down then up again to set the FastAddress number.
9.
Press the FOCUS or the IRIS button to store the FastAddress number. The on-screen
display menu confirms that the camera stored the FastAddress number.
Setting Passwords
Passwords are used to control access to locked command menus. Unlocked commands are
available to all users. Passwords are four (4) digits in length.
Special Passwords
The table below identifies special passwords and their function and security level.
Password
Function / Security Level
0000 (default)
Enables security and requires a user to enter the unlock command
OFF-90-ENTER before invoking a locked command.
9999
Disables all security and allows all users to access locked
commands.
Setting Passwords, Bosch Protocol
To set or change a password (locked command):
1.
Press OFF-90-ENTER to turn off the command lock.
2.
Press SET-802-ENTER to access the password menu.
3.
Tilt the joystick up or down to choose a number. Tilt the joystick right to move to the next
number position.
4.
Follow the on-screen instructions and save the password. You receive an on-screen
confirmation.
12.7
12.7.1
12.7.2
MIC Series 550
Getting Started | en
35
Bosch Security Systems, Inc.
Operation Manual
November 2011 | | F.01U.239.454