4. Cut a hole in the tile using the bracket as a
template (FIGURE 6).
Figure 6 Cutting the Tile
5. Secure the bracket assembly to an overhead
securing point using a safety cable (FIGURE 7).
Figure 7 Safety Cable Fitment
4.4
Address and Dip Switch Settings
Before installing the backbox, set the Address and S105
switches (FIGURE 8). Setting the Address switch to 0000
(NOT RECOMMENDED) responds to all messages
regardless of address; otherwise, the unit will only respond
to commands issued for that address.
The following dip switch settings pertain to AutoDome
Versions 5.00 and newer.
*Default position for all switch settings is OFF.
**Switch 1 Baud Rate only applies to a special mode to
download new firmware.
Figure 8 S105 Dip Switch and Address Switch
4.5
Backbox Module Mounting
Mount the backbox into the installed bracket assembly as
follows.
1. Verify that the edge of the hole will support the unit.
If the edge is uneven or slightly too large, attach the
appropriately colored (white/black) mounting ring, as
shown in FIGURE 9 and FIGURE 10. If the backbox
fits correctly, go directly to SECTION 4.6.
Figure 9 Mounting Ring Fitment
Installation
EN
© 2003 Bosch Security Systems
Page 9 of 16
S105 Dip Switch
Address Switch
Switch # Function
Position
Selection
**1
Boot Mode Baud Rate
(Firmware download only)
ON
OFF
19.2K
57.6K*
2
Serial Mode Selection
ON
OFF
RS-485
RS-232*
3
Camera Mode Selection
ON
OFF
Boot Loader Mode
Normal Mode*
4
Low Pressure Detection
ON
OFF
Pressurized Dome
Non-Pressurized
Dome*