background image

 General information  

en

13

:

Warning

Risk of fire!

Grease deposits in the grease filter may catch 

fire. The specified safety distances must be 

observed in order to prevent an accumulation 

of heat. Observe the specifications for your 

cooking appliance. If gas and electric hobs 

are operated together, the largest specified 

distance applies.

Only one side of the appliance may be 

installed directly next to a high-sided unit or a 

wall. The distance between the appliance and 

wall or high-sided unit must be at least 50 

mm. 

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

:

Warning

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the 

appliance from the electricity supply. The 

appliance must only be connected to a 

protective contact socket that has been 

correctly installed. If the plug is no longer 

accessible once the appliance has been 

installed, or a fixed connection is required, the 

installation must have an all-pole isolating 

switch with a contact gap of at least 3 mm. 

Only an electrician may install the fixed 

connection. We recommend installing a 

residual-current circuit breaker (RCCB) in the 

appliance's power supply circuit.

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

K

General information

General i

nformatio

n

Exhaust air mode

:

Warning

Risk of death!

Risk of poisoning from flue gases that are drawn back 

in. The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be conveyed 

into a non-functioning smoke or exhaust gas flue, you 

must obtain the consent of the heating engineer 

responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The appliance manufacturer does not provide any 

warranty for faults attributable to the pipe section.

The appliance achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long, rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

150 mm diameter, approx. 177 cm

2

120 mm diameter, approx. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for different pipe diameters.

‘

‘

‘

‘

Содержание LI67SA560B

Страница 1: ...Register your product online siemens home com welcome HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Страница 2: ...is appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by childr...

Страница 3: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Страница 4: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Страница 5: ...des Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through...

Страница 6: ... fan Press the A button Setting the brightness Press and hold the A button until the desired brightness is reached Saturation display When the metal grease filters or the activated charcoal filter are is saturated an audible signal will sound for approximately 4 seconds after the fan is switched off In addition the corresponding symbol will appear on the display Metal grease filter Activated charc...

Страница 7: ...ion display When the metal grease filters or the activated charcoal filter are is saturated an audible signal will sound for approximately 4 seconds after the fan is switched off In addition the corresponding symbol will appear on the display Metal grease filter Activated charcoal filter If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter rep...

Страница 8: ...tch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning agents When cleaning the metal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note...

Страница 9: ...mesh grease filter upwards locking it in place 3Trouble shooting Troubleshooting Malfunctions often have simple explanations Please read the following notes before calling the after sales service Warning Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective...

Страница 10: ...several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO GB 0344 892 8999 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Accessory Order number Basic equipment Starter set for circulating a...

Страница 11: ...idual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm PP PP ...

Страница 12: ...ependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room ai...

Страница 13: ... an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information Generalinformation Exhaust air mode Warning Risk of death Risk of poisoning from flue gases that ar...

Страница 14: ...upply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking appliances specify a different distance the largest distance must always be provide...

Страница 15: ...ces to the body on the left and right 3 Remove the tabs from the bottom of the mounting pieces ª Preparing the appliance A handle strip must be screwed to the filter pull out This handle strip can be one that is provided with the appliance or one that is available as an accessory 1 Use the screws provided to secure the handle strip to the filter pull out 2 Connect the power cord provided to the ap...

Страница 16: ...dimension Sliding out the appliance Note Before you remove the appliance protect the hob with a piece of polystyrene from the packaging 1 Use a flat blade screwdriver to push in the fastening bolt and turn it 90 until it locks into place 2 Push in the fastening bolt gently with your fingers and turn it until it comes out of the housing along with the spring Pull gently on the fastening bolt before...

Страница 17: ...ing The intermediate floor must not be placed on the extractor hood s housing The front panel must not be secured to the housing Access must be available in order to change the filter and for the after sales service Appliance width 90 cm You must also screw the appliance to the wall hanging cupboards either side of it Changing the filter pull out s limit stop On some versions of the appliance the ...

Страница 18: ...or and seal the joint Exhaust air pipe dia 120 mm 1 Fit the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Removing the appliance 1 Disconnect the electrical connection 2 Disconnect the pipes 3 Remove the metal grease filter 4 Remove the protective caps from the fastening elements 5 Remove the appliance...

Страница 19: ...6 ...

Страница 20: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001057558 9001057558 960211 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...

Отзывы: