background image

Home Connect    

en

11

Connecting to the app

If the Home Connect app is installed on your mobile 

device, you can connect it to your extractor hood.

Notes

The appliance must be connected to the network.

The app must be open.

1.

Press and hold the 

&

 symbol until the 

D

 and 

 

indicators start flashing.

2.

On your mobile device, follow the instructions in the 

Home Connect app.

The connection process is complete when the 

D

 

indicator stops flashing on the control panel and 

remains continuously lit.

Software update

Using the software update function, your extractor 

hood's software can be updated (e.g. for the purpose of 

optimisation, troubleshooting or security updates). To 

do this, you need to be a registered Home Connect 

user, have installed the app on your mobile device and 

be connected to the Home Connect server. 
As soon as a software update is available, you will be 

informed through the Home Connect app and will be 

able to start the software update via the app. 
Once the update has been successfully downloaded, 

you can start installing it via the Home Connect app if 

you are on your local area network.
The Home Connect app will inform you once installation 

is complete.

Notes

You can continue to use your extractor hood as 

normal while updates are downloading.

Depending on your personal settings in the app, 

software updates can also be set to download 

automatically.

We recommend that you install security updates as 

soon as possible.

Remote diagnostics

If a fault occurs, the after-sales service can use remote 

diagnostics to access your appliance.
Contact the after-sales service, making sure that your 

appliance is connected to the Home Connect server 

and checking that the remote diagnostics service is 

available in your country.

Note: 

For more information and to check whether the 

remote diagnostics service is available in your country, 

please visit the Help & Support area of the Home 

Connect website for your country: www.home-

connect.com

Resetting the connection

You can reset the connections you have saved on your 

home network and on Home Connect at any time.
Press and hold the 

!

 and 

&

 symbols until the 

D

 symbol goes out. When the audible signal is 

switched on, an audible signal sounds.

About data protection

When your appliance is connected for the first time to a 

WLAN network, which is connected to the Internet, your 

appliance transmits the following categories of data to 

the Home Connect server (initial registration):

Unique appliance identification (consisting of 

appliance codes as well as the MAC address of the 

installed WiFi communication module).

Security certificate of the WiFi communication 

module (to ensure a secure IT connection).

The current software and hardware version of your 

domestic appliance.

Status of any previous resetting to factory settings.

This initial registration prepares the Home Connect 

functions for use and is only required when you want to 

use these Home Connect functions for the first time.

Note: 

Ensure that the Home Connect functions can be 

used only in conjunction with the Home Connect app. 

Information on data protection can be accessed in the 

Home Connect app.

Declaration of Conformity

BSH Hausgeräte GmbH hereby declares that the 

appliance which features Home Connect is in 

accordance with the basic requirements and the other 

relevant provisions of the directive 2014/53/EU.
A detailed RED Declaration of Conformity can be found 

online at www.siemens-home.bsh-group.com on the 

product page of your appliance with the additional 

documents.

2.4 GHz band: max. 100 mW 

5 GHz band: max. 100 mW

y

BE

BG

CZ

DK

DE

EE

IE

EL

ES

FR

HR

IT

CY

LV

LT

LU

HU

MT

NL

AT

PL

PT

RO

SI

SK

FI

SE

UK

NO

CH

TR

5 GHz Wi-Fi: for indoor use only

Содержание LF91BUV50B

Страница 1: ...5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH EVK JURXS FRP ZHOFRPH en Instructions for installation and use Extractor hood ...

Страница 2: ......

Страница 3: ... perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea ...

Страница 4: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Страница 5: ...k Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while ...

Страница 6: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Страница 7: ...res slide your finger to the left across control panel III to select the fan setting you require Lighting The lighting can be switched on and off independently of the fan Touch the symbol Setting the brightness Press and hold the symbol until the desired brightness is reached Boost function Switching on Touch the symbol Note After approximately 20 seconds the extractor hood automatically switches ...

Страница 8: ...s and activated charcoal filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 12 Note The saturation indicator does not apply for non renewable activated charcoal filters that are inserted downstream of the metal grease filter These activated charcoal filters must be replaced twice a year Th...

Страница 9: ...a the hood controls on the hob If the extractor hood is being operated by means of the controls on the hood itself this mode of operation always has priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on and is i...

Страница 10: ...nually logging into your home network The extractor hood cannot be switched on during the connection process You can cancel the process at any time by pressing the symbol To connect the extractor hood to your home network the hood and the light must be switched off 1 Press and hold the symbol until the D and Ù indicators start flashing 2 To start automatic login to your home network swipe right ov...

Страница 11: ...ote For more information and to check whether the remote diagnostics service is available in your country please visit the Help Support area of the Home Connect website for your country www home connect com Resetting the connection You can reset the connections you have saved on your home network and on Home Connect at any time Press and hold the and symbols until the D symbol goes out When the au...

Страница 12: ...e Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand 2 Take the metal grease filter out of the h...

Страница 13: ... rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Pla...

Страница 14: ...isit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for y...

Страница 15: ...r is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers W...

Страница 16: ...ncoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or...

Страница 17: ...es that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer...

Страница 18: ...ation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit 5Installation InstallationFitting the upper support frame 1 Before fitting determine the total height of the support frame and mark the screw holes Note The height of the support frame can be adjusted in 20 mm intervals 2 On the ceiling mark...

Страница 19: ...nd seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective f...

Страница 20: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 6 DXVJHUlWH PE DUO HU 6WU 0 QFKHQ VLHPHQV KRPH EVK JURXS FRP 50 1 9001359533 9001359533 980215 ...