![Bosch L 309 Series Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/bosch/l-309-series/l-309-series_technical-information_47708023.webp)
Connection instructions
Type L 309
Power Supply Module
10
1070 078 131-104 (00.05) GB
- Connect the
PE bolt
of the power supply module’s base plate with a centralized
earthing point. Please ensure a sufficient cable cross-section!
- Lead mains
connection L1*
(cf. dimensioned drawings in ”Dimensions” sec-
tion) as an auxiliary phase of mains phase L1 to flat connector X3/7 (L1) of the
power supply module’s circuit board using a suitable cable (1.5 mm
2
min., short-
circuit-proof).
- The conductor cross-sections for phase L2 and the welding transformer’s out-
going feeder V must be dimensioned depending on the connected load.
- Connect phase
L2
to the marked thyristor connection using a cable lug for
threaded bolts and a suitable bolt.
- Connect outgoing welding transformer feeder
V
to the marked thyristor connec-
tion using a cable lug for threaded bolts and a suitable bolt.
NOTE
Bolted cable lug connections must be properly tightened. Use second wrench, if
necessary.
V
L2
L1
X3/7
PE
PE
5.2. Water connection
The cooling water connections are located at the back of the power supply mod-
ule’s base plate (dimensions and connections see dimensioned drawings in ”Di-
mensions” section). If the module is directly installed at the housing or switch cabi-
net wall, cooling water lines in the actual housing/switch cabinet are not necessary.
CAUTION!
- Check the cooling water lines for leaks before switching the mains voltage on.
- Ensure that the required water throughput is guaranteed and that the max. wa-
ter inlet temperature is not exceeded (see ”Cooling” in ”Technical data” section)!
!
Содержание L 309 Series
Страница 1: ...Power Supply Module Technical Information L 309 150 L 309 250 104 Edition ...
Страница 3: ......
Страница 5: ...Flexible Automation Type L 309 Power Supply Module 1070 078 131 104 00 05 GB ...
Страница 15: ...Flexible Automation Type L 309 Power Supply Module Structure 2 1070 078 131 104 00 05 GB ...
Страница 27: ...Maintenance Type L 309 Power Supply Module 14 1070 078 131 104 00 05 GB ...
Страница 31: ...Dimensioning instructions Type L 309 Power Supply Module 18 1070 078 131 104 00 05 GB ...
Страница 33: ...Fault messages Type L 309 Power Supply Module 20 1070 078 131 104 00 05 GB ...
Страница 36: ...A 1 1070 078 131 104 00 05 GB 1070 078 131 104 00 05 GB TI WS AT VWS Printed in Germany ...