Operating noises
Quite normal noises
Droning
Motors are running (e.g. refrigerating
units, fan).
Bubbling, humming or gurgling noises
Refrigerant is flowing through the tubing.
Clicking
Motor, switches or solenoid valves are
switching on/off.
Cracking
Automatic defrosting is running.
Preventing noises
The appliance is not level
Please align the appliance with a spirit
level. Use the height-adjustable feet
or place packing underneath them.
The appliance is not free-standing
Please move the appliance away
from adjacent units or appliances.
Containers or storage areas wobble
or stick
Please check the removable parts
and re-insert them correctly if required.
Bottles or receptacles are touching
each other
Move the bottles or receptacles slightly
away from each other.
Eliminating minor faults yourself
Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice – even if the appliance is still under
guarantee!
Fault
Possible cause
Remedial action
The light does not function.
The bulb is defective.
Replace bulb. Fig.
'
1. Pull out mains plug or switch off fuse.
2. Change the bulb.
(Replacement bulb, 220–240 V a.c., E14
bulb holder, see defective bulb for
wattage.)
Light switch is sticking.
Check whether it can be moved. Fig.
!
/8
Displays do not illuminate.
Power failure; the fuse has
been switched off; the mains
plug has not been inserted
properly.
Connect mains plug. Check whether the power
is on, check the fuses.