background image

 

 

 

 Bosch Security Systems, Inc. 
130 Perinton Parkway 
Fairport, NY 14450 
USA 

www.boschsecurity.com

 

© Bosch Security Systems, Inc., 2010 

F01U167054-01 
Installation Guide 

8/10

ISW-EN4200 Serial Receiver

Page 4 of 4

 

4.0

 

Register the RF Transmitters 

You must register all transmitters and repeaters with the 
ISW-D8125CW-V2. Bosch Commercial Wireless devices employ 
wireless registration, so there is no need to connect the transmitter 
to the ISW-D8125CW-V2. No data is written to the transmitter 
during registration. 

To register transmitters and repeaters (end devices): 

1.

 

Program the transmitter as described in the ISW-D8125CW-V2 
Installation and Operation Guide
 (P/N: F01U161691). 

2.

 

When prompted by the ISW-D8125CW-V2, press the RESET 
button on the end device. 

Press the end device

s RESET button once if the 

ISW-D8125CW-V2 is set to accept registration after a 
single reset message 

Press the end device

s RESET button twice if the 

ISW-D8125CW-V2 is set for a double button push. 

Depending on which ISW-EN4200 Serial Receiver received 
the reset message, either the RX1 LED or the RX2 LED on 
the ISW-D8125CW-V2 lights when the first reset message 
is received. 

Depending on which ISW-EN4200 Serial Receiver received 
the reset message, either the RX1 LED or the RX2 LED on 
the ISW-D8125CW-V2 lights when the last reset message is 
received.  

3.

 

When the end device is successfully registered, the 
ISW-D8125CW-V2 shows 

Programmed

 on its keypad display. 

4.

 

From the control panel, perform a walk test to ensure all 
registered devices work as expected. To perform a walk test, 
refer to your control panel documentation. 

5.0

 

ISW-EN4200 LEDs 

Use the following LEDs to monitor serial receiver operation. 

Refer to Table 1 below and Figure 1 on page 1. 

 

Table 1: 

ISW-EN4200 LEDs 

LED 

Description 

TX Transmit 

LED 

Lights when the serial receiver is transmitting 
data to the ISW-D8125CW-V2. 

RX 

Receive LED 

Lights when the serial receiver is receiving data 
from the ISW-D8125CW-V2. 

DEC Decode 

LED 

Lights when the serial receiver is decoding an RF 
transmission from a Commercial Wireless device. 

 

6.0

 

Specifications 

Housing Dimensions 
(H x W x D) 

162 x 91.4 x 27.9 mm 
(6.4 x 3.6 x 1.1 in.) 

Weight 

14.2 g (0.5 oz) 

Power Requirements 

12 VDC at 1 W 

Maximum Current Draw 

100 mA 

Operating Environment 

0

°

 to 60

°

C (32

°

 to 140

°

F), 90% 

relative humidity, non-condensing 

Compatible Control 
Panels 

 

GV3 Series: D9412GV3, 
D7412GV3, D7212GV3 

 

GV2 Series: D9412GV2, 
D7412GV2, D7212GV2 

 

G Series: D9412G, D7412G, 
D7212G 

 

9000 Series: D9412, D9112, 
D7412, D7212 
(Firmware 6.3 or later) 

 

 

 

 

Содержание ISW-EN4200 Serial

Страница 1: ...emoved from metal Metal objects duct work wire mesh screens boxes reduce RF range 2 0 Configuration Bosch Commercial Wireless products use a range of radio frequencies and must be configured for your geographic area All selection jumpers are shipped in their default positions Figure 1 If you want to keep the default selections setting the jumpers is not necessary The ISW EN4200 ships configured fo...

Страница 2: ...the ISW D8125CW V2 Commercial Wireless Interface Module within 20 ft 6 m of and within the same room as the ISW EN4200 4 Connect the ISW D8125CW V2 to the control panel For all versions of the D7412 and D7212 Control Panels you can connect one ISW D8125CW V2 Commercial Wireless Interface Module and up to two ISW EN4200 Serial Receivers Refer to Figure 2 below For all versions of the D9412 Control ...

Страница 3: ...X2 RX2 GND Vs RX TX GND Vs RX TX GND ZONEX BUS RECEIVER 2 RECEIVER 1 12V TX1 RX1 GND 12V IN OUT GND 12V TX2 RX2 GND Vs RX TX GND Vs RX TX GND 3 1 4 5 2 6 7 1 ISW D8125CW V2 connected to Zonex 1 on control panel Points 9 to 127 2 ISW D8125CW V2 connected to Zonex 2 on control panel Points 129 to 247 3 Control Panel 4 ISW EN4200 Receiver RECEIVER 1 on first ISW D8125CW V2 5 ISW EN4200 Receiver RECEI...

Страница 4: ...nding on which ISW EN4200 Serial Receiver received the reset message either the RX1 LED or the RX2 LED on the ISW D8125CW V2 lights when the last reset message is received 3 When the end device is successfully registered the ISW D8125CW V2 shows Programmed on its keypad display 4 From the control panel perform a walk test to ensure all registered devices work as expected To perform a walk test ref...

Отзывы: