ISW-EN4200 Serial Receiver Installation Guide 

8/10 | F01U167054-01 | 3

 

 

 

Figure 3: ISW-D8125CW-V2 to D9412 (GV3, GV2, and G) and D9112 Control Panel Wiring Diagram 

ZONEX OUT 2

ZONEX IN 2

ZONEX POWER +

ZONEX COMMON

23

24

25

26

27

28

ZONEX OUT 1

ZONEX IN 1

ZONEX BUS

RECEIVER 2

RECEIVER 1

+12V

TX1

RX1

GND

+12V

IN

OUT

GND

+12V

TX2

RX2

GND

Vs
RX
TX

GND

Vs
RX
TX

GND

ZONEX BUS

RECEIVER 2

RECEIVER 1

+12V

TX1

RX1

GND

+12V

IN

OUT

GND

+12V

TX2

RX2

GND

Vs
RX
TX

GND

Vs
RX
TX

GND

3

1

4

5

2

6

7

 

1 - 

 

ISW-D8125CW-V2 connected to Zonex 1 on control panel (Points 9 to 127) 

2 - 

 

ISW-D8125CW-V2 connected to Zonex 2 on control panel (Points 129 to 247) 

3 - 

 

Control Panel 

4 - 

 

ISW-EN4200 Receiver (RECEIVER 1 on first ISW-D8125CW-V2) 

5 - 

 

ISW-EN4200 Receiver (RECEIVER 2 on first ISW-D8125CW-V2) 

6 - 

 

ISW-EN4200 Receiver (RECEIVER 1 on second ISW-D8125CW-V2) 

7 - 

 

ISW-EN4200 Receiver (RECEIVER 2 on second ISW-D8125CW-V2) 

 

 

 

Содержание ISW-EN4200 Serial

Страница 1: ...emoved from metal Metal objects duct work wire mesh screens boxes reduce RF range 2 0 Configuration Bosch Commercial Wireless products use a range of radio frequencies and must be configured for your geographic area All selection jumpers are shipped in their default positions Figure 1 If you want to keep the default selections setting the jumpers is not necessary The ISW EN4200 ships configured fo...

Страница 2: ...the ISW D8125CW V2 Commercial Wireless Interface Module within 20 ft 6 m of and within the same room as the ISW EN4200 4 Connect the ISW D8125CW V2 to the control panel For all versions of the D7412 and D7212 Control Panels you can connect one ISW D8125CW V2 Commercial Wireless Interface Module and up to two ISW EN4200 Serial Receivers Refer to Figure 2 below For all versions of the D9412 Control ...

Страница 3: ...X2 RX2 GND Vs RX TX GND Vs RX TX GND ZONEX BUS RECEIVER 2 RECEIVER 1 12V TX1 RX1 GND 12V IN OUT GND 12V TX2 RX2 GND Vs RX TX GND Vs RX TX GND 3 1 4 5 2 6 7 1 ISW D8125CW V2 connected to Zonex 1 on control panel Points 9 to 127 2 ISW D8125CW V2 connected to Zonex 2 on control panel Points 129 to 247 3 Control Panel 4 ISW EN4200 Receiver RECEIVER 1 on first ISW D8125CW V2 5 ISW EN4200 Receiver RECEI...

Страница 4: ...nding on which ISW EN4200 Serial Receiver received the reset message either the RX1 LED or the RX2 LED on the ISW D8125CW V2 lights when the last reset message is received 3 When the end device is successfully registered the ISW D8125CW V2 shows Programmed on its keypad display 4 From the control panel perform a walk test to ensure all registered devices work as expected To perform a walk test ref...

Отзывы: