IR Illuminator 5000
Connection | en
7
Bosch Security Systems B.V.
Installation note
9.2018 | 2.2 | AM18-Q0715
Adjustments
8 mm
To adjust the sensitivity (Photocell adjust
1
):
1.
Use a thick flathead screwdriver to remove the protective sealing cap
1
.
2.
Use a small screwdriver to adjust the internal control:
–
To use the remove switching control input, turn the control fully counterclockwise.
(Now the IR LED lights when the green and blue wires are not connected; it does not
light when the wires are connected.)
–
To set the light level at which the illuminator switches on, turn the control
counterclockwise to turn on the illuminator when there is more light; turn it
clockwise to turn it on when it is darker. (The factory setting turns on the illuminator
at approximately 30
lx and turns it off at approximately 70
lx.)
3.
Put the protective sealing cap back in place and secure.
To adjust the IR intensity (Power adjust
2
):
1.
Use a thick flathead screwdriver to remove the protective sealing cap
2
.
2.
Using a small screwdriver, turn the internal control counterclockwise to reduce the IR
intensity. (The factory default is maximum power.)
3.
Put the protective sealing cap back in place and secure.