6
en | Connection
IR Illuminator 5000
9.2018 | 2.2 | AM18-Q0715
Installation note
Bosch Security Systems B.V.
3
Connection
3.1
Connecting the IIR-50xx0
+
-
WH
YE
GN
BU
RD
BK
{
{
6
5
4
3
2
1
Power
–
To power the illuminator, connect a 12 to 32
VDC or a 24
VAC supply from a SELV class 2
power supply to wires 5
(+
red) and 6
(-
black).
Notice!
Make sure the unused wires are not connected to each other.
Illuminator masters the camera
To use the light sensor in the illuminator to switch the day/night function of the camera:
1.
Connect wires 1
(+
white) and 2
(-
yellow) to the alarm input of the camera.
2.
If required, adjust the
Photocell adjust
control to determine the switching points of the
illuminator.
Camera masters the illuminator
To control illuminator switching from the camera:
1.
Turn the
Photocell adjust
control fully counterclockwise.
2.
Connect a relay output from the camera to wires 3
(-
green) and 4
(+
blue).