4
Product Diagram
Product Characteristics
Model
BOSCH 10H
BOSCH 13H
BOSCH 16H
Inlet Gas Pressure NG
1.13 kPa
1.13 kPa
1.13 kPa
Inlet Gas Pressure LPG
2.75 kPa
2.75 kPa
2.75 kPa
Burner Gas Pressure NG
0.89 kPa
0.84 kPa
0.78 kPa
Burner Gas Pressure LPG
2.60 kPa
2.60 kPa
2.60 kPa
NHGC
79 Mj/hr
104 Mj/hr
130 Mj/hr
Maximum Water flow at 50°C rise
5 l/min
6.5 l/min
8 l/min
Maximum Water flow at 25°C rise
10 l/min
13 l/min
16 l/min
Minimum water flow rate
3.2 l/min
3.2 l/min
3.2 l/min
Note:
Your water heating appliance requires a hot water flow rate of 3.2 litres per minute
and above to operate.
Water fixtures with a flow rate of 7.5 litres per minute or higher are recommended.
Your water heating appliance is not recommended for use on Solar, Spa or
recirculation systems.
1. Main Cover
2. Inspection Window
3. Cold Water Inlet
4. Gas Inlet
5. Hot Water Outlet
6. Mounting Point
7. Horizontal Flue
Dimensions
A
B
C
D
E
10H
405mm
845mm 533mm 240mm
68mm
13H
405mm 845mm 533mm 240mm
68mm
16H
450mm 936mm 533mm 240mm
82mm