1 692 106 011
2019-03-26
|
Robert Bosch GmbH
Checking / calibration | HTD 6xx / HTD 8xx | 65
en
4.6
Luminous intensity – HTD 8xx
1.
Position the beam setter in front of the calibration
device.
i
The distance should be 20 - 30 cm.
2.
Check the position of the spirit level in the light box.
In the event of deviation from the center position,
perform any necessary adjustment with the screws on
the trolley.
2.
Check if the green laser line runs through the center
point of the pendulum (Fig. 17). If necessary, adjust
the vertical by means of the adjusting screw on the
balance weight.
1
2
3
4
5
Fig. 17:
Checking the pendulum's vertical
1 Reflection
table
2 Rotation
center
3 Counterweight
4 Adjusting
screw
5 Green, vertical laser line
3.
After successful adjustment, cover adjusting screw
with tape.