6 720 817 986 (2015/07)
HPC 400
Working with the main menu | 21
5.3.3 Extra DHW heating
This menu allows you to set how DHW heating operates when
the extra DHW function is activated.
Menu:
Extra hot water
5.3.4 Thermal disinfection
Following thermal disinfection, the cylinder content slowly
cools back down to the set DHW temperature. The cool down is
effectuated mainly through heat losses. Consequently, the
DHW temperature may briefly be higher than the selected
temperature.
The thermal disinfection safeguards the hygienic quality of the
DHW. The hot water is heated regularly to the set temperature.
This also kills off legionella, for example. Thermal disinfection
can be configured in this menu.
Menu:
Thermal disinfection
Activate constant DHW heating
▶ If the standard display is active, press the DHW key.
▶ Turn the selector to highlight
Always on - DHW red.
or
Always on - DHW
.
▶ Press the selector.
DHW heating is active uninterrupted.
Always on - DHW
will result in a higher energy consumption and sound level than
Always on - DHW red.
.
Operating the appliance
Result
Table 19 Adapting the settings for DHW heating
6 720 811 136-28.1O
Menu item
description
Start now
/
Cancel
This menu item enables the extra DHW
function to be started and cancelled. Its
function is the same as the extra DHW key.
Temperature
When the extra DHW function is active, the
DHW is heated to the temperature set here.
Duration
The extra DHW function switches off
automatically after the set time.
Table 20 Extra DHW heating settings
CAUTION:
Legionnaire's bacteria constitute a
health hazard!
▶ At low hot water temperatures thermal
disinfection or daily heating should be
activated
1)
(
note the drinking water
statute).
1) Daily heating can be set by your installer in the service
menu.
WARNING:
Risk of scalding!
If thermal disinfection has been activated to
avoid legionella, the hot water is heated once to
in excess of 65 °C (e.g. Thursday night at
02:00).
▶ Only schedule thermal disinfection for
periods outside normal usage times.
▶ Make sure that a mixer is installed. If in
doubt, ask your contractor.
Menu item
description
Start
The entire DHW volume is only heated to the
set temperature once a week or once a day if
Auto
is set here.
Start now
/
Cancel
Immediate start or termination of the
thermal disinfection independent from the
set day of the week
Temperature
Temperature of the entire DHW volume at
thermal disinfection (65 ... 80 °C)
Day
The day on which thermal disinfection is
performed.
Time of day
Time of day for the automatic start of
thermal disinfection
Max. period
If the thermal disinfection temperature is
not reached within the time set here,
thermal disinfection is cancelled. The user
interface then issues a fault in the display.
Table 21 Settings for the thermal disinfection
ARUN-TWIN.
data in mm.
500, 600, 750, 900
1194
1754
2154
ARUN-TWIN model:
Standard design
The
ARUN-TWIN
model is the choice for perfectly tasteful and functional partitioning
of living space. It is convincing with its striking design and high fl exibility: variable wall
installation possible with no limitations.
Your advantages:
Elegance down to the
last detail guarantees a sophisticated
interior design.
RAL 3005
wine red
VOGEL
&
NOOT
CLIMATE CONTROL
SYSTEMS
Содержание HPC 400
Страница 44: ......