Removing the magnetron
3.7
1
. Remove the housing.
2
. Discharge the HV capacitor.
3
. Remove the magnetron TCO.
4
. Disconnect the magnetron.
5
. Remove the left air guide.
6. Unscrew the magnetron.
NOTE:
When re-installing the magnetron, ensure that the fastening screws
are tightened to prevent microwave energy from escaping. Also
ensure that there is no gap between the hollow conductor and
magnetron.