3.4 Removing the cooling fan
1. Remove the housing.
2. Discharge the HV capacitor.
3. Unscrew the H.V. diode.
4. Disconnect the magnetron.
5. Disconnect the fan motor.
6. Unscrew and remove the cooling fan assembly.
7. Unscrew the fan retaining plate and remove in the direction of the
structure.
Page 12 of 23 pages
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
______________________________________________________________________________________________________________________________________________________________________________
Copyright by BSH Home Appliances Corporation 1901 Main Street, Suite 600, Irvine CA 92614 700_ 58300000192890_ARA_EN_A 800 444-9091