10

HOT WATER CONNECTION TO WATER HEATER.

Refer to Technical Sheet for position of connection. The outlet connection is 18 mm (3/4"
BSP) MALE thread, and requires an isolating union to allow for removal of the unit.
Keep the pipe lengths to a minimum, and make sure that the pipework is well insulated as
correct performance of the appliance is dependent on properly insulated pipework.
DO NOT FIT ANY VALVES OR RESTRICTORS TO THE OUTLET OF THE WATER
HEATER.
DO NOT FIT ANY OBSTRUCTION TO THE PRESSURE RELIEF LOCATED ON THE
HOT WATER OUTLET CONNECTION.
After purging the air from the system using the hot water supply taps, remove the water inlet
strainer located on the cold water supply inlet connection.  Remove any debris from the filter
and replace.  When replacing the filter, do not over-tighten the “O” ring seal.

ELECTRICAL CONNECTION

The appliance is equipped with a 1.7 metre cable with a three pinned earthed plug
to be connected to a 240V, 50Hz supply. The electrical rating of the appliance is
0.4 Amps
The appliance requires a 240V in Australia and 230V in New Zealand, 50Hz
weatherproof plug installed in a protected position adjacent to the appliance.

IMPORTANT: The appliance should always be disconnected from the power
supply before any maintenance is carried out. 

If the power cord is damaged and

requires replacement, use only an original spare part available from the manufacturer.

PRE-SET TEMPERATURE

The Bosch water heaters are factory pre-set to operate at 55°C (or 50°C on 50
degree model) without temperature selector pads. The pre-set temperatures can be
altered to 60°C or 75°C, (or 42°C on 50 degree limited unit) by changing the setting
of the CPU or by using the temperature bridges supplied. Refer to page 13 for
details.
The appliance can also be fitted with temperature selector pads, available as an
accessory item. When fitted, the hot water will be delivered at the temperature
displayed on the selector pad.
There are two versions of remote controls available, the 66 series which has bath fill
alarm and the 67 series which has bath fill stop. 

The two different series must never be connected to the same water heater.
The Bathroom controller cannot be used as a sole controller.

There is a Main, Bathroom and Ensuite control available in each series, never
connect more than one of each control type to the water heater (except an extra sub
controller as the fourth controller.)

Only one of each type can be connected to the appliance.

Installation/Operating Instructions

Invented for life

Main controller

YPRM67XB

YPRM66XB

Max temperature 75° C #

Bathroom controller

YPRS67XB

YPRS66XB

Max temperature 50°C

Ensuite controller

YPRP62XB

YPRP62XB

Max temperature 50°C

67 series (Bathstop)

66 series (Bathfill)

# MAXIMUM TEMPERATURE IS CONTROLLED BY THE MAXIMUM DEFAULT

TEMPERATURE SET IN THE WATER HEATER

Содержание Highflow 17e

Страница 1: ... fitting regulations To be installed and serviced only by an authorised person This appliance is not suitable for use as a pool heater The authorised installing person is responsible for 1 Correct commissioning of this appliance 2 Ensure unit performs to the specifications stated on the rating label 3 Demonstrate operation of unit to customer before leaving 4 Hand these instructions to customer Fa...

Страница 2: ...nnection 10 Electrical Connection 10 Pre Set Temperature 10 Temperature Selector Pad Installation 11 Temperature Selector Pad Wiring 11 Temperature Control Operation 12 Commissioning and Testing 12 Temperature Setting 13 USER SAFETY INSTRUCTIONS 15 In Case Of Difficulties 15 Warranty Details 16 INDEX Installation Operating Instructions Invented for life ...

Страница 3: ...mperature selector pads have a maximum temperature setting of 50 C for safety To ensure compliance with Australian Standard AS NZS 3500 4 in the bathroom area this may be achieved by using a Bosch appliance limited to 50 C or using a Bosch appliance with a delivery temperature greater than 50 C and installed with a tempering valve high performance In New Zealand please refer to the New Zealand Bui...

Страница 4: ...r connection Pressure relife valve and Water drain valve Earth connection screw Bottom of case Air inlet Flue terminal DIMENSIONS YS2670RA 590 592 567 622 600 120 60 84 44 48 10 10 133 49 318 320 268 10 50 120 40 97 40 109 85 178 37 338 47 10 11 170 31 350 334 253 42 25 Power cable intaking hole Power cable intaking hole PS flame installation pich PS flame installation pich Perspective drawing fro...

Страница 5: ...ad 20mm Hot water connection male thread 20mm Relief valve pressure setting 1600 kPa DATA PLATE Fitted inside of cabinet GAS TYPE The gas type is nominated on a temporary label located on the front cover and on the data plate located inside of cabinet The gas type is the gas on which this appliance is designed to operate DO NOT OPERATE WITH ANY OTHER GAS TYPE WARNING LABELS Located on the right si...

Страница 6: ...00 Appliances over 200 MJ h input up to 250 MJ h input 1500 500 k Froma mechanicalair inlet including spablower 1500 1000 n Verticallybelow an openablewindow non mechanicalair inlet or any other opening into a building with the exception of sub floor ventilation Spaceheatersup to 50 MJ h 150 150 Other appliancesup to 50 MJ h 500 500 Appliancesover 50 MJ h and up to 150 MJ h input 1000 1000 Applian...

Страница 7: ...prevention device Thermal fuse Over heat prevention device Burner manifold Remote Control Connections Hot water temperature change connector Ignition plug Flame rod Flame failure safety device Gas solenoid valve set Printed circuit board Water flow rate adjusting valve Gas connection Outlet water connection Power cable Inlet water connection YS1770RA YS2170RA ...

Страница 8: ...emote Control Connections Burner manifold Thermal fuse Flue terminal Antifrost heater High limit switch Earth leakage breaker Water flow rate adjusting valve Flame rod Inlet water connection Power cable Outlet water connection Gas connection Controller Remote Empty heating prevention device Over heat prevention device Flame failure safety device YS2670RA ...

Страница 9: ... to technical sheet for position of connections The WATER INLET connection is 20 mm 3 4 BSP and requires a union to allow for removal of the water heater Pipe sizing from the cold water supply should be sized according to local BY LAWS for water supply If sludge or foreign matter is present in the water supply it is recommended that a separate filter strainer be fitted to the cold water supply lin...

Страница 10: ...requires replacement use only an original spare part available from the manufacturer PRE SET TEMPERATURE The Bosch water heaters are factory pre set to operate at 55 C or 50 C on 50 degree model without temperature selector pads The pre set temperatures can be altered to 60 C or 75 C or 42 C on 50 degree limited unit by changing the setting of the CPU or by using the temperature bridges supplied R...

Страница 11: ...emove control if necessary TEMPERATURE SELECTOR PAD WIRING DETAILS 1 Remove the front cover of the water heater and locate the PCB on the right hand side of the cabinet 2 Locate the two control terminals on the PCB Please be aware that all controller terminals connect back to the same two points on the PCB 3 Connect one end of the cable to the back of the controller using the terminal points provi...

Страница 12: ...e installation of the unit connect manometer to gas inlet test point turn on the water power and gas supplies to the unit Confirm the water heater delivers the temperature the consumer requires With the hot water running confirm correct gas inlet pressure and remove manometer Retighten test point and soap test Test operation of the appliance explain operation to consumer hand over these installati...

Страница 13: ... 50 C 42 C Bridge A 75 C 50 C Connected remote controller Unit YS1770RA YS2170RA YS2670RA Factory Setting 37 55 C Bridge B 37 60 C 37 50 C 37 50 C Bridge A 37 75 C 37 50 C Remote controller YPRM66XB YPRS66XB 37 55 C 37 60 C 37 75 C YPRM67XB 37 50 C 37 50 C 37 50 C YPRS67XB 37 50 C 37 50 C 37 50 C YPRP62XB 37 50 C 37 42 C 37 50 C 37 42 C 37 50 C 37 50 C YPRM66XB YPRS66XB 37 50 C 37 42 C 37 50 C YPR...

Страница 14: ...for life Step 2 Turn off power to unit Step 3 Insert bridge into plastic clip between the controller terminals Step 4 Turn power back on Unit is now set as per the table on the previous page PCB Controller Switch Modulation Adjust Setting Remote A B ...

Страница 15: ...flows or the Water Heater may go out without warning 5 Warning If the appliance does not operate burns with yellow flame leaks water or a gas smell is evident turn off and contact the local gas authority the manufacturer or an authorized service person IN CASE OF DIFFICULTIES If the Bosch water heater ceases to operate please check that the electricity supply is available Check for display of temp...

Страница 16: ...imited to the replacement or repair at the option of RBAU of any defective products and of such parts of RBAU s products as have been damaged in consequence of the defect despite proper treatment Parts replaced will not be returned c I Repairs and maintenance shall not extend the warranty period of the appliance ii If the product is located outside of the service agent s area the consumer shall be...

Отзывы: