Installation instructions
en
39
G20/
G25
G20
G20
G25
G25
G25.3
G30/G31
G30
G30
G27
Gas pressure (mbar)
20/25
20
25
20
25
25
28–
30/37
50
37
20
Nozzle (mm)
0.97
0.97
0.91
1
0.94
0.94
0.65
0.58
0.62
1
Bypass nozzle (mm)
0.58
0.58
0.58
0.58
0.58
0.58
0.38
0.38
0.38
0.58
Max. input power (kW)
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
Min. input power (kW)
≤0.9
≤0.9
≤0.9
≤0.9
≤0.9
≤0.9
≤0.9
≤0.9
≤0.9
≤0.9
Gas flow at 15 °C and
1013 mbar m
3
/h
0.167/
0.194
0.167
0.167
0.194
0.194
0.190
-
-
-
0.203
Gas flow at 15 °C and
1013 mbar g/h
-
-
-
-
-
-
127/125
127
127
-
Nozzle values for the (4 kW) wok burner
Note the following information for the gas types that are listed in the table for some burners.
G20/
G25
G20
G20
G25
G25
G25.3
G30/G31
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–30/37
50
37
Nozzle (mm)
1.48
1.48
1.38
1.50
1.45
1.45
1
0.88
0.94
Bypass nozzle (mm)
0.88
0.88
0.88
0.88
0.88
0.88
0.55
0.55
0.55
Max. input power (kW)
4
4
4
4
4
4
4
4
4
Min. input power (kW)
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
Gas flow at 15 °C and
1013 mbar m
3
/h
0.381/
0.443
0.381
0.381
0.443
0.443
0.433
-
-
-
Gas flow at 15 °C and
1013 mbar g/h
-
-
-
-
-
-
291/286
291
291
Nozzle values for the (3.5 kW) wok burner
Note the following information for the gas types that are listed in the table for some burners.
G20/
G25
G20
G20
G25
G25
G25.3
G30/G31
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–30/37
50
37
Nozzle (mm)
1.38
1.38
1.30
1.43
1.36
1.36
0.90
0.73
0.85
Bypass nozzle (mm)
0.88
0.88
0.88
0.88
0.88
0.88
0.55
0.55
0.55
Max. input power (kW)
3.5
3.5
3.5
3.5
3.5
3.5
3.3
3.3
3.3
Min. input power (kW)
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
≤1.7
Gas flow at 15 °C and
1013 mbar m
3
/h
0.333/
0.388
0.333
0.333
0.388
0.388
0.379
-
-
-
Gas flow at 15 °C and
1013 mbar g/h
-
-
-
-
-
-
240/236
240
240
Nozzle values for the lower burner in the gas oven with thermostat
Note the following information for the gas types that are listed in the table for some burners.
G20/G25
G20
G20
G25
G25
G25.3
G30
G30
Gas pressure (mbar)
20/25
20
25
20
25
25
28–
30
50
Nozzle (mm)
1.16
1.16
1.10
1.34
1.21
1.21
0.85
0.75
Bypass nozzle (mm)
0.76
0.76
0.67
0.80
0.70
0.70
0.48
0.45
Max. input power (kW)
3
3
3
3
3
3
3
3
Min. input power (kW)
-
-
-
-
-
-
-
-