SAFETY PRECAUTIONS

FITTING & MODIFICATIONS:

Fitting the appliance and any controls to the
appliance may only be carried out by a 
competent engineer in accordance with the 
relevant Installation Regulations.

Flue systems must not be modified in any 
way other than as described in the fitting 
instructions.

Any misuse or unauthorised modifications to 
the appliance, flue or associated 
components and systems could invalidate 
the warranty. The manufacturer accepts no 
liability arising from any such actions, 
excluding statutory rights.

This appliance is suitable for use with 28 
second kerosene only, no other fuel must
be used.

SERVICING:

The user must have the system regularly 
serviced by a competent, qualified OFTEC 
registered engineer using approved spares, 
to help maintain the economy, safety and 
reliability of the appliance.

The appliance should be serviced once each
year after installation unless the installation 
conditions and usage demand more frequent
services.

DO NOT OPERATE THE APPLIANCE WHEN:

4

The appliance, flue or system is incorrectly 
fitted, faulty or damaged.

4

The flue terminal outlet fitted on the outside 

wall or roof is obstructed or damaged.

4

There are fumes, fuel leaks or fuel smells 
from the fuel supply, appliance or flue system.

4

The system is empty, frozen or unpressurised
(sealed systems).

4

The condensate pipe is blocked or restricted.

4

The appliance clearances are inadequate.

4

The air supply is restricted or vents damaged.

INTRODUC

TION

OIL SMELLS, LEAKS OR FUMES FROM THE
APPLIANCE:

4

Extinguish any naked flames.

4

Open windows and doors.

4

Switch off the appliance electricity supply.

4

Isolate the fuel supply to the boiler.

4

Contact installer/service engineer.

HEALTH & SAFETY:

The appliance contains no asbestos and no 
substances have been used in the 
construction process that contravene the 
COSHH Regulations (Control of 
Substances Hazardous to Health 
Regulations 1988). Where applicable, the 
CE mark indicates compliance with relative 
EU Directives.

COMBUSTIBLE AND CORROSIVE
MATERIALS:

Do not

store or use any combustible 

materials (paper, thinners, paints etc.) inside 
or within the vicinity of the appliance.

The combustion air must be kept clear of 
chemically aggressive substances which can
corrode the appliance and invalidate any 
warranty.

SAFETY PRECAUTIONS

 

Содержание Greenstar Camray Utility 12/18

Страница 1: ...PUMPED OPEN VENT OR SEALED CENTRAL HEATING SYSTEMS AND DOMESTIC HOT WATER CYLINDERS For use with the following Greenstar oil fired appliances Greenstar Camray Utility 12 18 18 25 25 32 Greenstar Camray Utility System 12 18 18 25 25 32 THE APPLIANCE IS FOR USE WITH 28 SECOND KEROSENE ONLY GB USER INSTRUCTIONS CUSTOMER CARE GUIDE ...

Страница 2: ...OMER CARE GUIDE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR APPLIANCE THESE INSTRUCTIONS ARE APPLICABLE TO THE WORCESTER BOSCH GROUP APPLIANCE MODEL S STATED ON THE FRONT COVER OF THIS MANUAL ONLY AND MUST NOT BE USED WITH ANY OTHER MAKE OR MODEL OF APPLIANCE IF YOU ARE IN ANY DOUBT CONTACT THE WORCESTER BOSCH GROUP TECHNICAL HELPLINE PLEASE KEEP THESE INSTRUCTIONS WITH THE INST...

Страница 3: ...NS 2 EXCELLENCE COMES AS STANDARD 3 GENERAL INFORMATION 4 6 USING YOUR APPLIANCE CONTROLS 7 OPERATING THE APPLIANCE Switching the boiler on off 8 Setting the heating temperature 8 Controlling central heating 8 Fault conditions 9 ENERGY SAVING TIPS ON ENERGY SAVING 10 11 MAINTENANCE MAINTAINING YOUR APPLIANCE 12 FAULT FINDING 13 FAULT OR BREAKDOWN 14 GUARANTEE YOUR GUARANTEE 15 GUARANTEE REGISTRATI...

Страница 4: ...4 The appliance flue or system is incorrectly fitted faulty or damaged 4 The flue terminal outlet fitted on the outside wall or roof is obstructed or damaged 4 There are fumes fuel leaks or fuel smells from the fuel supply appliance or flue system 4 The system is empty frozen or unpressurised sealed systems 4 The condensate pipe is blocked or restricted 4 The appliance clearances are inadequate 4 ...

Страница 5: ...ance for more than 40 years This heritage means all products are of exceptional quality and proven reliability The condensing range in particular is extremely energy efficient converting more of the fuel consumed into heat offering you economical running costs and value for money It sits in SEBUK band A at the top of the energy rated appliances available There is also the assurance of our no nonse...

Страница 6: ... the bottom then it should be vented by releasing air through the venting screw at the top of the radiator Ask your installer to show you how this is done Repeated venting will reduce the quantity of water in the system and this must be replenished for safe and satisfactory operation of the appliance When excessive venting or water leaks are found in the system you must contact a service engineer ...

Страница 7: ...led under a worktop as long as 4 The worktop above the boiler is removable for maintenance 4 There is at least 10mm clearance above the boiler 4 The front of the boiler is not enclosed VENTILATION Air vents must be functional at all times and the air supply must not be restricted or contaminated The appliance clearances must meet the minimum shown opposite for servicing and venting purposes If thi...

Страница 8: ...ommunicate with a protected area such as a hall stairway landing corridor lobby shaft etc 4 Air vents must allow access for clean free air and must be sited to comply with the flue terminal position requirements 4 Air ducting runs must not exceed 3m 4 Low level air vents must be less than 450mm from the floor 4 A warning label must be added to the vents with a statement to the effect Do not block ...

Страница 9: ...l B Reset button burner lock out indicator reset button on the burner control box behind the front panel C Reset button boiler overheat thermostat behind front panel D Reset button flue overheat thermostat behind front panel E Front panel CONTROLS USING YOUR APPLIANCE C A D UTILITY UTILITY SYSTEM MODELS E B 7 ...

Страница 10: ... turn the programmer timer to OFF for heating and hot water If the appliance is left unused and exposed to freezing conditions shut off all the mains supplies isolate the boiler and drain the system and boiler SETTING HEATING TEMPERATURE 4 Turn the control clockwise to increase the radiator temperature 4 Turn the control anti clockwise to reduce the radiator temperature The minimum and maximum ran...

Страница 11: ...g 1 Check oil level in the oil storage tank 2 Press button B Boiler should fire 3 If no response wait 2 minutes press reset button B again 4 If lockout light stays on do not attempt further resets Contact your service engineer for advice c Light OFF boiler not on no heating hot water 1 Ensure there is a power supply to the boiler 2 Check the programmer is set to ON for heating 3 Check the setting ...

Страница 12: ... preferably to a minimum thickness of 200mm Window frames Single glazed windows particularly those with steel frames can lose a great deal of heat Consideration should be given to replacement with PVCu or wooden framed double glazed units Curtains Lined curtains or heavier full length curtains can provide excellent insulation However always ensure that the curtains do not drape over radiators Drau...

Страница 13: ...ture and tables in front of the radiator should also be avoided It is advisable to manually adjust all radiator valves every 2 3 months to prevent them from sticking It is also important that the plastic tops of all valves are always in position and not cracked or damaged to help prevent accidents Care should be taken when vacuum cleaning carpets to avoid damage to valves and pipework The heating ...

Страница 14: ...k Please tick the appropriate box on your warranty registration card for further details on the Worcester Bosch Group service contract In addition to the service contract we are pleased to offer a one off annual service or breakdown cover When your appliance requires servicing please contact the Worcester Bosch Group contact centre see inside front cover for details Maintenance tips Regularly chec...

Страница 15: ...unt Temperature rises instead of falling No display or display unit does not respond Hot water temperature too low Radiators are too hot Clock is incorrectly set Momentary power failure Hot water tank temperature set too low Hot water not in timed period on the programmer Temperature control on boiler set too low Increase thermostatic radiator valve setting s Increase temperature control setting B...

Страница 16: ...liance has been installed for over 24 months OR 4 Our Field Service Engineer finds no fault with the appliance see Note OR 4 Evidence cannot be provided that the first year service inspection has been carried out i e an entry in the service interval record found at the rear of the appliance installation and servicing manual OR 4 The cause of breakdown is misuse or with other parts of your plumbing...

Страница 17: ... out to the satisfaction of BBT Thermotechnology UK Ltd when requested The guarantee card must then be returned within 30 days of installation 4 That any product or part thereof returned for servicing under the guarantee must be accompanied by a claim stating the Model Serial Number and Date of Installation 4 That BBT Thermotechnology UK Ltd will not accept responsibility for damage caused by faul...

Страница 18: ...days of installation Returning your card will register you as the owner of your new appliance and will assist us in maintaining an effective and efficient customer service by establishing a reference and permanent record for your boiler This does not affect your statutory rights For your own record GUARANTEE REGISTRATION GREENSTAR CAMRAY UTILITY UTILITY SYSTEM 12 18 18 25 25 32 8 716 111 983a 02 0...

Страница 19: ...NOTES NOTES NOTES GREENSTAR CAMRAY UTILITY UTILITY SYSTEM 12 18 18 25 25 32 8 716 111 983a 02 07 17 NOTES ...

Страница 20: ...EXCELLENCE COMES AS STANDARD Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 01905 754624 Fax 01905 754619 www worcester bosch co uk Worcester Bosch Group is a brand name of BBT Thermotechnology UK Ltd 8 716 111 983a 02 07 ...

Отзывы: