32
| English
– The discrepancy
d
between the two marked points
Ⅰ
and
Ⅲ
on wall A reveals the ac-
tual horizontal deviation of the measuring tool.
The maximum permitted deviation on the measuring distance of 2 ×
5
m =
10
m is as fol-
lows:
10
m × ±
0.3
mm/m = ±
3
mm. The discrepancy
d
between points
Ⅰ
and
Ⅲ
must therefore
amount to no more than
3
mm.
Checking the Level Accuracy of the Vertical Line
For this check, you will need a door opening (on solid ground) which has at least 2.5 m of
space either side of the door.
– Place the measuring tool 2.5 m away from the door opening on a firm, flat surface (not
on a tripod). Switch on the measuring tool in the mode with automatic levelling. Se-
lect vertical mode and allow the measuring tool to level in.
2,5 m
2,5 m
– Mark the centre of the vertical laser line
on the floor of the door opening
(point
Ⅰ
), 5 m away on the other side of
the door opening (point
Ⅱ
) and on the
upper edge of the door opening
(point
Ⅲ
).
2 m
d
– Set up the measuring tool on the other
side of the door opening, directly behind
point
Ⅱ
. Allow the measuring tool to level
in and align the vertical laser line in such
a way that its centre passes through
points
Ⅰ
and
Ⅱ
exactly.
– Mark the centre of the laser line on the upper edge of the door opening as point
Ⅳ
.
– The discrepancy
d
between the two marked points
Ⅲ
and
Ⅳ
reveals the actual ver-
tical deviation of the measuring tool.
1 609 92A 7AN | (14.12.2021)
Bosch Power Tools
Содержание GLL 2-10 Professional
Страница 3: ... 3 2 1 1 3 4 Bosch Power Tools 1 609 92A 7AN 14 12 2021 ...
Страница 4: ...4 12 10 9 11 5 6 7 8 9 1 609 92A 7AN 14 12 2021 Bosch Power Tools ...
Страница 5: ... 5 13 14 16 15 RM 1 17 14 18 13 A B Bosch Power Tools 1 609 92A 7AN 14 12 2021 ...
Страница 6: ...6 C D E 1 609 92A 7AN 14 12 2021 Bosch Power Tools ...
Страница 7: ... 7 F G H Bosch Power Tools 1 609 92A 7AN 14 12 2021 ...