Flexidome
XT
| Installation Manual
EN
| 13
DIP switches
Use the four DIP switches on the printed circuitboard to set the following
functions:
1. BLC – Back Light Compensation (factory default: Off)
2. WB – White Balance (factory default: On)
3. NC – Night Sense (factory default: On)
4. LL – Line Lock (factory default: On)
If line lock is set to On, then you can adjust the V-phase to synronize the
picture with other AC powered cameras in the system. Use a small
screwdriver to rotate the V-phase control on the printed circuit board.
Camera positioning
The physical default position of the camera is that the top of the image
corresponds to the indication TOP.
Caution
The CCD image sensors are highly sensitive and require special
care for proper performance and extended lifetime. Do not expose
them to direct sunlight or bright spotlights in operating and non-
operating conditions. Avoid bright lights in the field of view of the
camera.
The camera module position can be adjusted along three axes. When
adjusting the camera position ensure that the picture display on the
monitor is level. Set the camera to the desired position by performing the
following steps:
• For horizontal adjustment, rotate the camera module in the base. Do
not rotate more than 360°.
• For vertical adjustment, loosen thumbscrews, position camera, then
gently tighten thumbscrews to secure camera.
• To obtain a horizontal horizon (for tilted ceilings or sidewall
mounting), rotate the base of the lens as necessary to align the picture
shown on the monitor. Do not rotate more than 360°.
Bosch Security Systems | 2005-02 | V2.0