34
en | Operation
EX65 Explosion-protected Camera
F.01U.412.061 | 2.0 | 2011.08
Instruction Manual
Bosch Security Systems, Inc.
8.5.6
Test signal submenu
8.5.7
Camera ID submenu
Bilinx Comms.
On, Off
If Off, Bilinx communications is disabled.
Camera buttons
Enable,
disable
Enable or disable the camera buttons from working.
Cable compensation Off, Default,
RG59, RG6,
Coax12
Cable compensation is used to avoid the need for
amplifiers in long distance coaxial connections up to
1000 m (3000 ft). For optimum results select the
coaxial cable type used or, if unknown, select default.
Compensation level
0,1,2 . . .+15
Sets the level of cable compensation
EXIT
Returns to Install menu.
Item
Selection
Description
Item
Selection
Description
Show camera ID Off, On
Select On to overlay the camera ID on the video test
signal.
Test pattern
Color bars 100%,
Grayscale 11-step,
Sawtooth 2H,
Checker board,
Cross hatch,
UV plane
Select the desired test pattern to help installation
and fault-finding.
EXIT
Returns to Install menu.
Item
Selection
Description
Camera ID
Enter a 17-character camera name. Use Left/Right to
change position in the string; use up/down to select
character. Use Select to exit.
Display ID pos.
Off, Top left,
Top right,
Bottom left,
Bottom right
Select the screen position of the camera ID.
Camera ID
border
On, Off
Displays a grey border behind the camera ID to make it
easier to read.
MAC address
Shows MAC address (factory set, cannot be changed).
Содержание EX65
Страница 1: ...EX65 Explosion protected Camera VEN 650 Series en Instruction Manual ...
Страница 2: ......
Страница 47: ......