Certifications and approvals

CSA-NRTL

LR 113310

Class

9098 01 / 81 - Miscellaneous - for Hazardous

Locations

Safety

UL / CSA

 

UL 508, Sixteenth Edition - Industrial Control

Equipment

 

UL 698, Eleventh Edition - Industrial Control

Equipment for Use in Hazardous (Classified)

Locations

 

UL 1203 Explosion-Proof and Dust-Ignition-Proof

Electrical Equipment for Use in Hazardous

(Classified) Locations

 

CSA C22.2 No.0-M1991 General Electrical

Requirements

 

CSA C22.2 No.0.4-M1982 Bonding and Grounding

of Electrical Equipment (Protective Grounding)

 

CSA C22.2 No.25-M1966 Enclosures for Use in

Class II Groups E, F, and G Hazardous Locations

 

CSA C22.2 No.30-M1986 Explosion-proof

Enclosures for Use in Class I Hazardous Locations

 

CSA C22.2 No.94-M1991 Special Purpose

Enclosures

 

CSA C22.2 No.142-M1987 Process Control

Equipment

 

Class I, Div 1, 2, Groups A, B, C, D

 

Class II, Div 1, 2, Groups E, F, G

 

Class III

Operational

Temperature Code T6 at maximum ambient

temperature 50ºC (122ºF)

Environmental

CSA / NEMA TYPE 4

Notice
Product is not ATEX certified.

Region

Certification

Canada

CSA

Installation/configuration notes

Dimensions

149 (5.9)

max

154 (6.1) max

368 (14.5)

128 (5.0)

89 (3.5)

mm (in)

Ø 108 (4.3)

Technical specifications

Electrical

Rated Voltage

12‑24 VDC

 

12‑24 VAC (50/60 Hz)

Power Consumption

40 W

Imager

Interline transfer CCD, 1/2-inch image

format

Active Pixels

 

PAL Model

752 H x 582 V

NTSC Model

768 H x 492 V

Sensitivity (3200 K, scene reflectivity 89%, F1.2)

 

Full video

(100 IRE)

Usable

picture

(50 IRE)

Usable picture

(30 IRE)

Color

1.40 lx

(0.13 fc)

0.31 lx

(0.029 fc)

0.0991 lx

(0.0097 fc)

Color

+ SensUp 10x

0.14 lx

(0.013 fc)

0.031 lx

(0.0029 fc)

0.00991 lx

(0.0009 fc)

Monochrome

0.57 lx

(0.053 fc)

0.121 lx

(0.0112 fc)

0.0391 lx

(0.0036 fc)

Monochrome

+ SensUp 10x

0.057 lx

(0.0053 f

c)

0.0121 lx

(0.00112 fc

)

0.00391 lx

(0.00036 fc)

 

Horizontal Resolution

540 TVL

Signal-to-Noise-Ratio

> 50 dB

Video Output

1 Vpp, 75 Ohm

Y/C Output

Y: 1 Vpp / C: 0.3 Vpp

2 | EX62XF Explosion-protected Camera

Содержание EX62XF

Страница 1: ...ter 1 2 inch CCD sensor The EX62XF is designed and certified for covering the entire range of North American Division requirements per the NEC Its stringent Class I Division 1 certifications allow safe functioning at locations where ignitable concentrations of flammable gases or liquid vapors are present during normal operation Groups covered include acetylene hydrogen ethylene and methane all hig...

Страница 2: ...F G Class III Operational Temperature Code T6 at maximum ambient temperature 50ºC 122ºF Environmental CSA NEMA TYPE 4 Notice Product is not ATEX certified Region Certification Canada CSA Installation configuration notes Dimensions 149 5 9 max 154 6 1 max 368 14 5 128 5 0 89 3 5 mm in Ø 108 4 3 Technical specifications Electrical Rated Voltage 12 24 VDC 12 24 VAC 50 60 Hz Power Consumption 40 W Ima...

Страница 3: ...four in NPT conduit entries Brackets Cradle with stainless steel straps included View Window Tempered glass Weight 8 5 kg 18 lb Dimensions 149 x 154 x368 mm 5 9 x 6 1 x 14 5 in including bracket and straps Environmental Operating Temperature 50 C to 50 C 58 F to 122 F Ordering information EX62XF6V0412H N Explosion protected Camera Explosion protected housing with Dinion2XF LTC 0630 4 12 mm lens he...

Страница 4: ...ndhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6571 2808 Fax 65 6571 2699 apr securitysystems bosch com www boschsecurity asia Bosch Shanghai Security Systems Ltd 201 Building No 333 Fuquan Road North IBP Changning District Shanghai 200335 Ch...