Certifications and approvals
CSA-NRTL
LR 113310
Class
9098 01 / 81 - Miscellaneous - for Hazardous
Locations
Safety
UL / CSA
UL 508, Sixteenth Edition - Industrial Control
Equipment
UL 698, Eleventh Edition - Industrial Control
Equipment for Use in Hazardous (Classified)
Locations
UL 1203 Explosion-Proof and Dust-Ignition-Proof
Electrical Equipment for Use in Hazardous
(Classified) Locations
CSA C22.2 No.0-M1991 General Electrical
Requirements
CSA C22.2 No.0.4-M1982 Bonding and Grounding
of Electrical Equipment (Protective Grounding)
CSA C22.2 No.25-M1966 Enclosures for Use in
Class II Groups E, F, and G Hazardous Locations
CSA C22.2 No.30-M1986 Explosion-proof
Enclosures for Use in Class I Hazardous Locations
CSA C22.2 No.94-M1991 Special Purpose
Enclosures
CSA C22.2 No.142-M1987 Process Control
Equipment
Class I, Div 1, 2, Groups A, B, C, D
Class II, Div 1, 2, Groups E, F, G
Class III
Operational
Temperature Code T6 at maximum ambient
temperature 50ºC (122ºF)
Environmental
CSA / NEMA TYPE 4
Notice
Product is not ATEX certified.
Region
Certification
Canada
CSA
Installation/configuration notes
Dimensions
149 (5.9)
max
154 (6.1) max
368 (14.5)
128 (5.0)
89 (3.5)
mm (in)
Ø 108 (4.3)
Technical specifications
Electrical
Rated Voltage
12‑24 VDC
12‑24 VAC (50/60 Hz)
Power Consumption
40 W
Imager
Interline transfer CCD, 1/2-inch image
format
Active Pixels
PAL Model
752 H x 582 V
NTSC Model
768 H x 492 V
Sensitivity (3200 K, scene reflectivity 89%, F1.2)
Full video
(100 IRE)
Usable
picture
(50 IRE)
Usable picture
(30 IRE)
Color
1.40 lx
(0.13 fc)
0.31 lx
(0.029 fc)
0.0991 lx
(0.0097 fc)
Color
+ SensUp 10x
0.14 lx
(0.013 fc)
0.031 lx
(0.0029 fc)
0.00991 lx
(0.0009 fc)
Monochrome
0.57 lx
(0.053 fc)
0.121 lx
(0.0112 fc)
0.0391 lx
(0.0036 fc)
Monochrome
+ SensUp 10x
0.057 lx
(0.0053 f
c)
0.0121 lx
(0.00112 fc
)
0.00391 lx
(0.00036 fc)
Horizontal Resolution
540 TVL
Signal-to-Noise-Ratio
> 50 dB
Video Output
1 Vpp, 75 Ohm
Y/C Output
Y: 1 Vpp / C: 0.3 Vpp