1. ANTI-TIP BRACKET INSTALLATION INSTRUCTIONS
- IMPORTANT SAFETY WARNING

To reduce the risk of tipping of the range, the range must be
secured to the floor by properly installed Anti-Tip Bracket and
screws packed with the range. Failure to install the anti-tip bracket
will allow the range to tip over if excessive weight is placed on an
open door or if a child climbs upon it. Serious injury might result
from spilled hot liquids or from the range itself.

If range is ever moved to a different location, the Anti-Tip Bracket
must also be moved and installed with the range.

Instructions are provided for installation in wood or cement
fastened to either the floor or wall.  When installed to the wall,
make sure that screws completely penetrate dry wall and are
secured in wood or metal.  When fastening to the floor or wall, be
sure that screws do not penetrate electrical wiring or plumbing.

1a. Locate the Bracket using the Template

 - 

(Bracket

may be located on either the left or right side of the range.  Use
the information below to locate the bracket if template is not

2a. Models with Factory Connected Power Supply

Cord

NOTE:

 

Some models may have a factory

installed three (3) conductor Power Supply Cord.

2. ELECTRICAL CONNECTION REQUIREMENTS -

 

This

appliance must be properly installed and grounded by a qualified
technician in accordance with the National Electrical Code ANSI/
NFPA No. 70 -- latest edition -- and Local Electrical Code
requirements.

This appliance may be connected by means of "Permanent
Wiring" or "Power Supply Cord Kit."

When installing Permanent Wiring, do not leave excess wire in
range compartment. Excess wire in the range compartment may
not allow the Rear Access Cover to be replaced properly and
could create a potential electrical hazard if wires become pinched.
Connect only as instructed under "

Permanent Wire

Connections

" in Step 4c.  When using flexible conduit or range

cable use flex connector or range cable strain relief (Fig. 11).

Fig. 4

Fig. 5

Fig. 6

Fig. 7

BEFORE STARTING
Tools You Will Need
For leveling legs and Anti-Tip Bracket:

• Adjustable wrench or channel lock pliers
• 5/16" Nutdriver or Flat Head Screwdriver
• Electric Drill & 1/8" Diameter Drill Bit
(Masonry Drill Bit if installing in concrete)

For electrical supply connection:

• 1/4" & 3/8" Socket driver or Nutdriver

Additional Materials You Will Need:

• Power Supply Cord or
• Copper Electrical Wiring & Metal Conduit

(for hard wiring)

NORMAL INSTALLATION STEPS

3/16" pilot hole 1-3/4" deep. The screws provided may be used
in wood or concrete material.  Use a 5/16" nut-driver or flat
head screwdriver to secure the bracket in place (See Fig. 6).

1c. Level and Position Range

 - 

Level range by adjusting

the (4) leveling legs with a wrench. NOTE: A minimum
clearance of 1/8" is required between the bottom of the range
and the leveling leg to allow room for the bracket.  Use a spirit
level to check your adjustments.  Slide range back into position
(See Fig. 7).
Visually check that rear leveling leg is inserted into and fully
secured by the Anti-Tip Bracket by removing lower panel or
storage drawer. For models with a Warmer Drawer or broiler
compartment, grasp the top rear edge of the range and carefully
attempt to tilt it forward.

available).
Mark the floor or wall where
left or right side of the range
will be located.  If rear of range
is against the wall or no
further than 1-1/4" from wall
when installed, you may use
the wall or floor mount
method. If molding is installed

and does not allow the bracket to fit flush against the wall, remove
molding or mount bracket to the floor. For wall mount, locate the
bracket by placing the back edge of the template against the rear
wall and the side edge of template on the mark made referencing
the side of the range (See Fig. 4). Place bracket on top of
template and mark location of the screw holes in wall.  If rear of
range is further than 1-1/4" from the wall when installed, attach
bracket to the floor.  For floor mount, locate the bracket by placing
back edge of the template where the rear of the range will be
located.  Mark the location of the screw holes, shown in template.

1b. Drill Pilot Holes & Fasten Bracket

 - 

Drill a 1/8" pilot

hole where screws are to be located.  If bracket is to be mounted
to the wall, drill pilot hole at an approximate 20° downward angle
(See Fig. 5).
If bracket is to be mounted to masonry or ceramic floors, drill a

Mobile home installations, new branch circuit installations
(1996NEC) or areas where Local Codes do not permit grounding
through neutral require a four (4) conductor power supply cord kit
rated at 125/250 volts minimum and marked for use with ranges.

See Range Connection Opening Size Chart  (Figs. 9 & 10) for
cord kit ampere rating information. Terminals on end of wires
must be either closed loop or open-end spade lugs with upturned
ends.

2

INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE

Содержание Evolution HES5L53U

Страница 1: ...EDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS p n 316454912 rev A If the information in this manual is not followed exactly a fire or electrical shock may result causing property damage personal injury or death Important Notes to the Installer Readallinstructionscontainedintheseinstallationinstructions before installing range Remove a...

Страница 2: ...ll Need Power Supply Cord or Copper Electrical Wiring Metal Conduit for hard wiring NORMALINSTALLATIONSTEPS 3 16 pilot hole 1 3 4 deep The screws provided may be used in wood or concrete material Use a 5 16 nut driver or flat head screwdriver to secure the bracket in place See Fig 6 1c Level and Position Range Level range by adjusting the 4 leveling legs with a wrench NOTE A minimum clearance of 1...

Страница 3: ... Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile home requires 4 Wire connection 1 Follow the manufacturer s installation instructions supplied with the strain relief and install Also see Figs 9 10 11 2 Insert the end connectors for Line 1 Line 2 and Neutral and...

Страница 4: ... installation instructions supplied with the strain relief and install 2 3 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal block Follow wire locations shown in Fig 14 IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure ...

Страница 5: ...MAS AFUERA DE LA PARTE INFERIOR DE LOS ARMARIOS English Pages 1 4 TODAS LAS ESTUFAS PUEDENVOLCARSE SEPUEDENCAUSAR LESIONES INSTALE EL DISPOSITIVO ANTIVUELCOINCLUIDO CON LA ESTUFA VEALASINSTRUCCIONES DEINSTALACION Fig 1 Fig 2 Fig 3 Sinosesigueestrictamentelainformaciónde este manual se puede producir un incendio o un choque eléctrico que cause daños materiales lesiones corporales o fatales Notas Im...

Страница 6: ...ELECTRICOS DE CONEXION Este artefacto debe ser instalado y puesto a tierra en forma correcta por un técnico calificado de acuerdo con el Código Nacional de ElectricidadANSI NFPANo 70 últimaedición ylosrequerimientos del código local de electricidad Este artefacto debe ser conectado mediante cableado permanente o el Juego de Cable de Alimentación Eléctrica Cuando instale el cableado permanente no d...

Страница 7: ...o de cable Juego de cable Cableado Permanente 1 3 8 1 3 8 1 1 8 1 3 8 40 50 Amp 50 Amp 8 8 16 5 KW 7 9 12 5 KW 16 6 22 5 KW 12 6 18 5 KW Fig 10 Cubierta de acceso trasera Disco removible de 29mm de diám Ver Tabla Agujero de 22 mm de diám Ver Tabla Placa de montaje Agujerode 35 mm de diám Ver Tabla Cavidad para la placa de montaje del cable Fig 11 Sujetacable Separe el sujetacable antes de la insta...

Страница 8: ...CHADO VerFig 7 Asegúresedequeelcordónde alimentación quede plegado en el resto del área abierta del piso detrás de la gaveta de almacenamiento o gaveta calentadora de la estufa Asegúrese de verificar la nivelación de la estufa o 4B CONEXIONES DEL CORDON DE ALIMENTACION Instrucciones para conexión trifilar para instalaciones existentes SOLAMENTE Consulte la Fig 13 1 Siga las instrucciones de instal...

Отзывы: