Installation
English 12
Connect Electric
There are two possible electrical connections:
1. Four wire range cord
2. Three wire range cord
The four wire range cord connection is the recommended method, but where local
codes permit, three wire connections are also acceptable.
For installations other than those in Canada, connect the range cord at the
terminal block (See next page for detailed instructions). Access the terminal block
by removing the cover in the lower right hand corner of the range back panel.
Install Strain Relief
Place strain relief in knockout below terminal block. See Figure 11: Strain Relief
Knockout.
1. In the knockout panel below the terminal block, remove the knockout that fits
your strain relief.
2. Feed range cord through hole and strain relief up to terminal block. Allow for
slack in the cord between the strain relief and terminal block.
3. Once cord length/ slack has been adjusted, attach strain relief per instructions
included with strain relief.
Note:
In Canada, the range is shipped from the factory with the range cord
already installed. Continue to “Connect Gas Supply” on page 16.
WARNING:
The strain relief provided with your range cord must be properly
installed.
Strain reliefs vary. Carefully read and follow the instructions included
with your strain relief.
Figure 11: Strain Relief Knockout
Tip:
The knockout panel below the terminal block can be removed from
the range to install the strain relief: Remove knockout panel from
range, install strain relief in panel and reattach. DO NOT remove
entire range back panel.
Содержание Evolution HDS7052U
Страница 27: ......