TALLER
External connections to the heat pump
These are the external connections that must be made for the heat pump:
Power supply 3-phase:
The power supply is connected to terminals L1, L2, L3, N and PE. In
the event of a possible phase sequence fault the heat pump will trip the alarm
3-phase incorrect
.
See more information in the section
What to do if a fault occurs
.
Power supply 1-phase:
The power supply is connected to terminals L, N, and PE.
Mixing valve on the heating circuit:
If a second heat curve with a mixing valve is to be used,
the mixing valve is connected to terminal block SV1.
External main pump in the heating system G1
(P1): The external main pump must be
connected to the terminal card in those cases a bypass is required. The pump is connected to
terminal P1.
Return sensor radiator T1 (GT1)
: Must always be connected. Connect to terminal GT1.
Outdoor sensor T2
(GT2): Must always be connected. Connect to terminal GT2.
Hot water sensor T3
(GT3): Is connected if the heat pump is to produce hot water. Connect
to terminal block GT3 X on the terminal card. On the LW model this sensor is already
connected on delivery.
Mixing valve sensor T4
(GT4): Is connected when a mixing valve for a second heat curve is
to be used. Connect to terminal GT4.
Room sensor T5
(GT5): Is connected if room sensor infl uence is required.
Mixing
valve
G1 (P1)
Terminal card
230 V
Retur
n radiator
Outdoor sensor
Hot water
Mixing valve
Room sensor
Alarm lamp, room sensor
Terminal card
for external
connections
Connecting the heat pump to the power supply