56
FOR THE INS
TALLER
Connecting the heat pump to the heating system
LW model: individual temperature control in each room, increasing
volume of internal water and bypass
This solution is viable if you want to control the temperature of each room, for example if you use thermostat valves on
the radiators in each room. The function of the heat pump is to maintain a temperature in accordance with the heat curve
(depending on outdoor temperature) in the accumulator. The heating water is then distributed from the accumulator to the
heating system. This solution also allows the overall volume of the installation to be increased if the volume of the heating
system is inadequate, for example with one or two fan-assisted radiators.
*
* Mixed heating system
There is a possibility to control a second
heating system with a mixing valve. This
is recommended when a combination of
radiators and a
fl
oor heating system is used.
C11: Expansion
tank
C21: storage
tank
E22 :
water heater with electric cassette
E42:
tank with outer shell
F21: safety
valve
G1 (P1): radiator pump
G2 (P2): heat carrier pump
G4 (P4): Pump for mixed heating system
Q41: mixer
valve
V21:
fi
lter heating system
V40: hot
water
W40:
cold water »