background image

en

    Connecting to a hob

10

e

Connecting to a hob

Connecting to a hob

You can connect this appliance to a hob (if the hob 

supports connection to the appliance) and then control 

the functions of the hood via your hob. 
Appliances can be connected to each other in different 

ways:

Home Connect

Two appliances can be connected using the Home 

Connect app provided that both of them are Home 

Connect compatible.
Refer to the Home Connect documents supplied for 

more information.

Connecting appliances directly

If the appliance is connected directly to a hob, it cannot 

be connected to your home network as well. The 

appliance will function as an extractor hood that is not 

connected to the network and you can continue to 

operate it via the control panel.

Connecting appliances via your home network

If the appliances are connected to each other via your 

home network, both the hood controls on the hob and 

Home Connect can be used to operate the appliance.

Notes

Make sure you follow the safety instructions in the 

instruction manual for your extractor hood and that 

these are complied with even when operating the 

appliance via the hood controls on the hob.

If the extractor hood is being operated by means of 

the controls on the hood itself, this mode of 

operation always has priority. It is not possible to use 

the hood controls on the hob during this time.

Setting up a connection

The hood must be switched off before you can connect 

the hob and extractor hood.

Connecting directly

Make sure that the hob is switched on and is in search 

mode.
To do this, refer to the section entitled "Connecting to 

the extractor hood" in the instruction manual for your 

hob.

Notes

Before connecting the appliance, reset all existing 

connections to the WiFi or other appliances.

If your extractor hood is connected directly to the 

hob, it cannot be connected to your WiFi as well and 

you will not be able to use Home Connect.

Press and hold the 

D

 symbol until it starts to flash.

The extractor hood has been connected to the hob 

when the 

D

 symbol stops flashing and remains 

continuously lit.

Connecting via your home network

Follow the instructions in the section entitled "Automatic 

login to your home network" or "Manually logging into 

your home network" 

~

 "Home Connect" on page 11

Once the extractor hood is connected to your home 

network, you can connect to the hob via the Home 

Connect app. To do this. follow the instructions on your 

mobile device.

Home Connect    

en

11

o

Home Connect

Home Connect

This appliance can be networked and also controlled 

using a mobile device. 
If the appliance is not connected to your home network, 

it will function as an extractor hood with no network 

connection and can still be operated via the display.
The availability of the Home Connect function depends 

on the availability of Home Connect services in your 

country. Home Connect services are not available in 

every country. You can find more information on this at 

www.home-connect.com.

Notes

Ensure that you follow the safety instructions in this 

instruction manual and that you comply with these 

even when you are away from home and are 

operating the appliance via the Home Connect app. 

You must also follow the instructions in the Home 

Connect app.

Operating the appliance directly from the appliance 

always takes priority. It is not possible to operate the 

appliance using the Home Connect app during this 

time.

Setting up

To implement settings via Home Connect, you must 

have installed and set up the Home Connect app on 

your mobile device.
Refer to the Home Connect documents supplied for 

more information.
The app will guide you through the entire registration 

process. Follow the steps specified by the app to 

implement the settings.
The app must be open in order to perform the set-up 

process.

Note: 

In networked standby mode, your appliance 

requires a maximum of 2 W.

Automatic registration in the home network
Notes

You require a router that has WPS functionality.

You require access to your router. If you do not have 

this, follow the steps for "Manually logging into your 

home network".

The extractor hood cannot be switched on during the 

connection process. You can cancel the process at 

any time by pressing the 

#

 symbol.

To connect the extractor hood to your home 

network, the hood and the light must be switched off.

1.

Press and hold the 

D

 symbol until it starts to flash.

2.

Press "1" to start automatic login to your home 

network.

The LED for fan setting 1

 

and the 

D

 symbol will 

flash.

3.

Press the WPS button on the router within the next 

2 minutes.

If the extractor hood has successfully connected, it 

will automatically connect to the Home Connect app. 

The LED for fan setting 3

 

and the 

D

 symbol will 

flash.

Note: 

If the extractor hood has been unable to 

connect, it will automatically allow you to manually 

connect to your home network. The LED for fan 

setting 2

 

and the 

D

 symbol will flash. Log the 

appliance into your home network manually or press 

"1" to try logging in automatically again.

4.

On your mobile device, follow the instructions for 

automatic network login.

The login process is complete when the 

D

 symbol 

stops flashing on the control panel and remains 

continuously lit.

Manual registration in the home network
Notes

The extractor hood cannot be switched on during the 

connection process. You can cancel the process at 

any time by pressing the 

#

 symbol.

To connect the extractor hood to your home 

network, the hood and the light must be switched off.

1.

Press and hold the 

D

 symbol until it starts to flash.

2.

Press "2" to manually log into your home network.

The LED for fan setting 2

 

and the 

D

 symbol will 

flash.

3.

Use the "Home Connect" SSID and the "Home 

Connect" key to log the mobile device into the 

extractor hood network.

If the extractor hood has successfully connected, it 

will automatically connect to the Home Connect app. 

The LED for fan setting 3

 

and the 

D

 symbol will 

flash.

4.

On your mobile device, follow the instructions for 

manually logging into your network.

The login process is complete when the 

D

 symbol 

stops flashing on the control panel and remains 

continuously lit.

Содержание DWK98PR60/02

Страница 1: ...3FHJTUFS ZPVS OFX EFWJDF PO Z PTDI OPX BOE HFU GSFF CFOFGJUT CPTDI IPNF DPN XFMDPNF en Instructions for installation and use Extractor hood ...

Страница 2: ...s installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appli...

Страница 3: ...In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Neve...

Страница 4: ... are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes o...

Страница 5: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Страница 6: ... Intermediate position for the glass front On some appliances the glass front can be adjusted to an intermediate position The intermediate position can be used for eliminating particularly strong cooking smells and large amounts of steam Take hold of the glass front in the centre and open it carefully Fan run on time Switching on Touch the y symbol The fan will run at fan setting 1 After approxima...

Страница 7: ... are flashing To do this touch the symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the D symbol Touch the 2 symbol Take your finger off the D symbol This will switch the electronic controller over to air recirculation mode filters ...

Страница 8: ...uch the symbol The fan will start at setting 2 2 Touch the symbol The optimum fan setting is set automatically using the PerfectAir sensor Switching off Touch or any fan setting to switch off automatic mode The fan switches itself off automatically if the PerfectAir sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Sensor control In aut...

Страница 9: ...will switch the electronic controller over to air recirculation mode filters that can be regenerated Repeatedly touching and holding the D symbol and touching the 1 symbol switches the electronic controller back over to air extraction mode Decorative LED lighting The decorative LED lighting can be switched on and off independently of the fan Touch the l symbol Setting the brightness Press and hold...

Страница 10: ...liance via the hood controls on the hob If the extractor hood is being operated by means of the controls on the hood itself this mode of operation always has priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on...

Страница 11: ... the process at any time by pressing the symbol To connect the extractor hood to your home network the hood and the light must be switched off 1 Press and hold the D symbol until it starts to flash 2 Press 1 to start automatic login to your home network The LED for fan setting 1 and the D symbol will flash 3 Press the WPS button on the router within the next 2 minutes If the extractor hood has suc...

Страница 12: ...set the connections you have saved on your home network and on Home Connect at any time Press and hold the and D symbols until the D symbol goes out When the audible signal is switched on an audible signal sounds About data protection When your appliance is connected for the first time to a WLAN network which is connected to the Internet your appliance transmits the following categories of data to...

Страница 13: ...Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold the glass front in the centre when doing so gripping it firmly 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your ...

Страница 14: ...nse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Place ...

Страница 15: ... appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed custom...

Страница 16: ...ilter for starter set DWZ0AK0U0 DWZ0AK0A0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set DWZ0AK0T0 DWZ0AK0A0 Starter set for air recirculation mode with filter that can be regenerated flat hood with chimney DWZ0AF0S0 Starter set for air recirculation mode with filter that can be regenerated flat hood without chim ney DWZ0AF0R0 Starter set for ...

Страница 17: ... hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD P...

Страница 18: ...tion location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The speci...

Страница 19: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Страница 20: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Страница 21: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Страница 22: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Страница 23: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Страница 24: ...N XFMDPNF PPLJOH GPS IFMQ PV MM GJOE JU IFSF YQFSU BEWJDF GPS ZPVS PTDI IPNF BQQMJBODFT OFFE IFMQ XJUI QSPCMFNT PS B SFQBJS GSPN PTDI FYQFSUT JOE PVU FWFSZUIJOH BCPVU UIF NBOZ XBZT PTDI DBO TVQQPSU ZPV XXX CPTDI IPNF DPN TFSWJDF POUBDU EBUB PG BMM DPVOUSJFT BSF MJTUFE JO UIF BUUBDIFE TFSWJDF EJSFDUPSZ 3PCFSU PTDI BVTHFSÉUF NC BSM 8FSZ 4USB F ßODIFO FSNBOZ XXX CPTDI IPNF DPN 9001159153 9001159153 9...

Отзывы: