background image

 General information  

en

13

:

Warning

Risk of fire!

Grease deposits in the grease filter may catch 

fire. The specified safety distances must be 

observed in order to prevent an accumulation 

of heat. Observe the specifications for your 

cooking appliance. If gas and electric hobs 

are operated together, the largest specified 

distance applies.

Only one side of the appliance may be 

installed directly next to a high-sided unit or a 

wall. The distance between the appliance and 

wall or high-sided unit must be at least 50 

mm. 

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

:

Warning

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the 

appliance from the electricity supply. The 

appliance must only be connected to a 

protective contact socket that has been 

correctly installed. If the plug is no longer 

accessible once the appliance has been 

installed, or a fixed connection is required, the 

installation must have an all-pole isolating 

switch with a contact gap of at least 3 mm. 

Only an electrician may install the fixed 

connection. We recommend installing a 

residual-current circuit breaker (RCCB) in the 

appliance's power supply circuit.

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

K

General information

General information

Exhaust air mode

:

Warning

Risk of death!

Risk of poisoning from flue gases that are drawn back 

in. The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be conveyed 

into a non-functioning smoke or exhaust gas flue, you 

must obtain the consent of the heating engineer 

responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The device manufacturer does not assume any 

warranty for complaints attributable to the pipe section.

The device achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

dia. 150 mm ca. 177 cm

2

dia. 120 mm ca. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for deviating pipe diameters.

Checking the wall

The wall must be level, vertical and adequately load-

bearing.

The depth of the bore holes must be the same 

length as the screws. The wall plugs must have a 

secure grip.

The enclosed screws and wall plugs are suitable for 

solid brickwork. Suitable fasteners must be used for 

other structures (e.g. plasterboard, porous concrete, 

poroton bricks).

The max. weight of the extractor hood is 

40 kg

.

Electrical connection

:

Warning

Risk of electric shock!

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

Содержание DWA097E51A

Страница 1: ...en Instructions for installation and use Extractor hood ...

Страница 2: ...ge which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible ...

Страница 3: ...te the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Risk of fire Hot oil and fat can ignite very quickly ...

Страница 4: ... slightly 1 slope 7Environmental protection EnvironmentalprotectionEnvironmentally friendly disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Bef...

Страница 5: ...nd hold the B button until the desired brightness is reached Saturation display When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should...

Страница 6: ...When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should be cleaned or the activated carbon filter changed now For instructions on how t...

Страница 7: ...too quickly or too slowly it can be changed accordingly 1 When the fan is switched off press the 1 button and hold it for approx 4 seconds The setting is displayed 2 Press the or button to change the setting of the sensor control 3 To confirm the entries press and hold the 1 button for approx 4 seconds Fan run on time The fan run on time is possible at every fan setting except boost and boost ƒ Se...

Страница 8: ...ning agents Cleaning agents with a high alcohol content Hard scouring pads or cleaning sponges High pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with the cleaning agents Cleaning the metal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described ...

Страница 9: ...d under the metal mesh grease filter 2 Fold the metal mesh grease filter upwards locking it in place 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please read the following notes before calling the after sales service Warning Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained ...

Страница 10: ...The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of opera...

Страница 11: ...d installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation 5 6 7 8 1 DHZ 5325 channel width 260 mm 2 DHZ 5326 channel width 260 mm 3 DHZ 5345 channel width 345 mm 4 DHZ 5346 channel width 345 mm 5 DSZ 6200 channel width 260 mm 6 DSZ 5201 channel width 260 mm 7 DSZ 6240 channel width...

Страница 12: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Страница 13: ...formation GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtai...

Страница 14: ... 3 mm Only an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit 5Installation InstallationPreparing the installation Caution Ensure that there are no electric wires gas or water pipes in the area where holes are to be made 1 Mark a vertical centre line on the wall from the ceiling to the lower edge o...

Страница 15: ...connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesi...

Страница 16: ...961015 9001017124 9001017124 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Отзывы: