Operating the appliance

These instructions apply to several appliance variants. It is 

possible that individual features are described which do not 

apply to your appliance.

Note: 

Switch on the extractor hood when you start cooking and 

switch it off again several minutes after you have finished 

cooking. This is the most effective way of removing the kitchen 

fumes.

Control panel

Setting the fan

Note: 

Always adjust the fan strength to meet current conditions. 

If there is a large build-up of steam or fumes, select a high fan 

setting.

Switching on the appliance

1.

Press the 

#

 button.

Fan setting 1 is set.

2.

Press the 

a

 button until the required fan setting is set.

The set fan setting is shown in the display panel. After the 

intensive setting, fan setting 1 is set.

Switching off the appliance

Press the 0 button.

Intensive setting

You can use the intensive setting if there is a large build-up of 

odours and fumes/vapours.

1.

Press the 

a

 button until fan setting 4 is displayed in the 

display panel.
The intensive setting is activated.

2.

Press the 

a

 button until fan setting 1 is displayed in the 

display panel.
The intensive setting is deactivated and fan setting 1 is set.

Note: 

The running time of the intensive setting is 5 minutes. 

Once this time has elapsed, the appliance switches back to fan 

setting 2.

Fan run-on time

The duration of the run-on time depends on the fan setting that 

is set:

Fan setting 1: 20 minutes 

Fan setting 2: 15 minutes

Fan setting 3: 10 minutes

Intensive setting: 5 minutes

1.

Select the fan setting.

2.

Press the 

0

 button.

The fan runs at the set fan setting. The indicator beside the 

set fan setting flashes. The ventilation automatically switches 

off once the run-on time has elapsed.

3.

Press the 

a

 button.

The fan run-on ends before the remaining run-on time 

elapses. Ventilation continues at the set fan setting.

4.

Press the 

0

 or 

#

 button.

The fan run-on ends before the remaining run-on time 

elapses. The ventilation is switched off.

Lighting

The lighting can be switched on and off independently of the 

ventilation.
Press the 

B

 button.

Saturation display

If the metal grease filter and the activated charcoal filter are 

saturated, the following numbers flash:

Metal grease filter: 

Activated charcoal filter: 

ƒ

Metal grease filter and activated charcoal filter: 

 and 

ƒ

 

flash alternately

When this happens, do not delay cleaning the metal grease 

filter or replacing the activated charcoal filter any further.
For instructions on how to clean the metal grease filter, refer to 

the section 

Cleaning and maintenance

.

Resetting a saturation indicator

Press and hold the 

#

 button until the saturation indicator no 

longer flashes.
The saturation indicator is reset.

Resetting the saturation displays

1.

Press and hold the 

#

 button until the saturation indicator for 

the metal grease filter no longer flashes.
The saturation indicator for the metal grease filter is reset.

2.

Press and hold the 

#

 button until the saturation indicator for 

the activated charcoal filter no longer flashes.
The saturation indicator for the activated charcoal filter is 

reset.

Switching over the display for circulating-air mode

For circulating-air mode, the electronic control display must be 

switched over accordingly:

1.

Check that the extractor hood is connected and switched off.

2.

Press the 

a

 and 

B

 buttons at the same time until the 

numbers 

 and 

ƒ

 flash alternately.

The electronic control is switched over to circulating-air 

mode.

Switching over the display for exhaust air mode

1.

Check that the extractor hood is connected and switched off.

2.

Press the 

a

 and 

B

 buttons at the same time until the 

number 

 flashes.

The electronic control is switched back to exhaust-air mode.

Explanation

1

Switch the fan on/off

2

Switch the fan setting up

3

Display panel

4

Switch on the lighting

5

Switch on the fan run-on

Содержание DWA06E621

Страница 1: ... en Instruction manual 3 pl Instrukcja obsługi 10 Extractor hood Okap DWA06E651 B DWA06E661 DWA06E621 ...

Страница 2: ......

Страница 3: ...s intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the a...

Страница 4: ...of fire Hot oil and fat can ignite very quickly Never leave hot fat or oil unattended Never use water to put out burning oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar Risk of fire When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may ...

Страница 5: ...u no longer require it Switch off the lighting if you no longer require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fire Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circula...

Страница 6: ...ilation continues at the set fan setting 4 Press the 0 or button The fan run on ends before the remaining run on time elapses The ventilation is switched off Lighting The lighting can be switched on and off independently of the ventilation Press the B button Saturation display If the metal grease filter and the activated charcoal filter are saturated the following numbers flash Metal grease filter...

Страница 7: ...fore use Follow all instructions and warnings included with the cleaning agents Cleaning the metal mesh grease filters Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least once a month Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning agents When cleaning the metal mesh grease filters also ...

Страница 8: ... the retainer 3 Insert the retainer into the extractor hood 4 Close the screw connections on the retainer 5 To fit the metal grease filter see above 6 Press and hold the button until the saturation indicator no longer flashes The saturation indicator is reset Trouble shooting Malfunctions often have simple explanations Please read the following notes before calling the after sales service Risk of ...

Страница 9: ...en calling us please give the product number E no and the production number FD no so that we can provide you with the correct advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it...

Страница 10: ...nieprawidłowym użytkowaniem lub błędną obsługą To urządzenie jest przeznaczone do użytku na wysokości do 2000 metrów nad poziomem morza Urządzenie mogą obsługiwać dzieci w wieku powyżej 8 lat oraz osoby z ograniczonymi zdolnościami fizycznymi sensorycznymi lub umysłowymi a także osoby nie posiadające wystarczającego doświadczenia lub wiedzy jeśli pozostają pod nadzorem osoby odpowiedzialnej za ich...

Страница 11: ... pozostawiać rozgrzanego tłuszczu lub oleju bez nadzoru Nigdy nie gasić ognia wodą Wyłączyć pole grzejne Ostrożnie stłumić ogień używając pokrywki koca gaśniczego lub podobnego przedmiotu Niebezpieczeństwo pożaru Włączone gazowe pola grzejne bez postawionych na nich naczyń wytwarzają dużo ciepła Może to prowadzić do uszkodzenia lub zapalenia się znajdującego się nad nimi wentylatora Gazowych pól g...

Страница 12: ...e należy usunąć zgodnie z przepisami o ochronie środowiska Tryby pracy Urządzenie można użytkować w trybie obiegu otwartego lub zamkniętego Praca w trybie obiegu otwartego Wskazówka Powietrza wylotowego nie wolno kierować do komina odprowadzającego spaliny lub dym ani do kanału wentylacyjnego pomieszczeń w których stoją urządzenia spalające Jeżeli powietrze wylotowe ma być kierowane do nieużytkowa...

Страница 13: ...stopień mocy 2 Nacisnąć przycisk 0 Wentylator pracuje na ustawionym stopniu mocy Miga wskaźnik obok ustawionego stopnia mocy wentylatora Po upływie czasu opóźnienia wyłączenia wentylatora system wentylacyjny wyłączy się automatycznie 3 Nacisnąć przycisk a Funkcja opóźnienia wyłączenia wentylatora zostanie wyłączona przed upływem zaprogramowanego czasu Wentylacja działa nadal na ustawionym stopniu ...

Страница 14: ...eniem do czyszczenia odczekać aż urządzenie ostygnie Niebezpieczeństwo porażenia prądem elektrycznym Przedostająca się wilgoć może spowodować porażenie prądem elektrycznym Urządzenie czyścić wyłącznie wilgotną ściereczką Przed czyszczeniem wyciągnąć wtyczkę lub wyłączyć bezpiecznik w skrzynce bezpiecznikowej Niebezpieczeństwo porażenia prądem Wnikająca wilgoć może spowodować porażenie prądem Nie u...

Страница 15: ...wania Wskazówka Tłuszcz może się gromadzić na dole metalowego filtra przeciwtłuszczowego Metalowy filtr przeciwtłuszczowy należy trzymać w pozycji poziomej aby zapobiec skapywaniu tłuszczu 2 Wyczyścić metalowy filtr przeciwtłuszczowy 3 Po demontażu filtra wyczyścić urządzenie od wewnątrz 4 Wyczyścić pokrywę filtra Montaż metalowego filtra przeciwtłuszczowego 1 Włożyć metalowy filtr przeciwtłuszczo...

Страница 16: ...eży podać symbol produktu nr E oraz numer fabryczny nr FD urządzenia aby mógł on udzielić kompetentnej pomocy Tabliczka znamionowa z tymi numerami znajduje się wewnątrz urządzenia widoczna po wyjęciu metalowego filtra przeciwtłuszczowego Można tu wpisać dane urządzenia i numer telefonu serwisu aby w razie konieczności szybko je odnaleźć Należy pamiętać że wezwanie technika serwisu w przypadku niep...

Страница 17: ...17 Wyposażenie dodatkowe urządzeń z obiegiem zamkniętym nie wchodzi w zakres dostawy DHZ5585 ...

Страница 18: ......

Страница 19: ......

Страница 20: ...960901 9000948722 9000948722 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Отзывы: