9
6. For rectangular ducted discharge installations
only
(otherwise skip to next step)
Attach exhaust adaptor/damper
over knockout
opening with two exhaust adaptor screws. Make sure
damper
pivot
is nearest to
top/back edge
of hood.
Remove
tape
from damper flap.
Exhaust
transition/damper
Pivot
Top/back
edge
NOTE:
The exhaust adaptor/damper can be
installed up to 1 inch on either side of the hood
center to accommodate off-center ductwork. In
extreme off-center installations, one end of the duct
connector may need to be trimmed to clear the
electrical cable clamp.
7. For round ducted discharge installations only
Re-install the
round transition
with its screws.
7" Round
Transition
NOTE:
The round transition can be installed up to 1
inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector
may need to be trimmed to clear the electrical cable
clamp.