A component that is not a field replaceable unit
failure has been detected.
SE+ dF+ blank-
–
A processor DIMM failure has been detected.
SE+ dF+ "--"+ CF+ Px + blank-
–
A cache memory DIMM failure has been detected.
SE+ dF+ "--"+ CF+ Cx + blank-
–
A processor DIMM or a cache memory DIMM failure
has been detected.
SE+ dF+ "--"+ CF+ dx + blank-
–
A host interface card failure has been detected.
SE+ dF+ "--"+ CF+ Hx + blank-
–
An incorrect number of cache backup devices have
been detected.
SE+ LC+ "--"+ CF+ Fx + blank-
Use cases
Repeating sequence
Use case
: Controller is suspended and there are no other
errors to report.
–
All lockdown conditions
OH+ Lx+ blank-
Use cases
Repeating sequence
Use case
: The controller is suspended because of
component errors.
–
Persistent processor DIMM error correcting code
(ECC) errors have been detected.
OE+ L2+ "--"+ CF+ CX+ blank-
–
Persistent cache DIMM ECC errors have been
detected.
OE+ L2+ "--"+ CF+ CX+ blank-
–
Persistent processor or cache DIMM ECC errors
have been detected.
OE+ L2+ "--"+ CF+ CX+ blank-
Use cases
Repeating sequence
Use case
: The controller has been suspended as a result
of persistent cache backup configuration errors.
–
The write-protect switch is set during cache restore. OE+ LC+ blank-
–
The memory size changed with dirty data in the flash
drives.
OE+ LC+ dd+ blank-
Use cases
Repeating sequence
Use case
: The controller has been suspended as a result
of diagnostic errors.
A cache memory diagnostic failure has been detected.
dE+ L2+ "--"+ CF+ Cx + blank-
A base controller diagnostic failure has been detected.
dE+ L3+ "--"+ CF+ b1 + blank-