The supervision features function as follows:

                      

Supervision Display Chart

LED

ON

2 Flashes
4 Flashes

CAUSE

Unit Alarm

Motion Monitor Timeout

PIR Self-test Failure

PIR:

  The operation of the PIR is electronically checked

approximately every 12 hours. If the PIR fails, the Alarm/Test
LED will flash four times and the Trouble Output will activate.

Motion Monitor Supervision:

  This feature verifies that the

detector has a clear view of the detection area and has not been
blocked. When selected using switches S4 and S5, a
supervision timer is activated. A trouble condition will be
indicated if the detector has not alarmed at least once during
the selected time period (this feature can be disabled by placing
both switches in the Off position). The time period selected
should be long enough to allow adequate time for holiday
weekends.

Refer to Section 6.0 (Configuration Switch Settings) for proper
switch settings.

If the time period selected has elapsed from the last alarm, the
LED will flash two times and the Trouble Output will activate.

Setting the Motion Monitor timer to shorter periods can be used
to force a protection walk test of remotely located zones.

It is recommended that the 30 day timer be selected. This
verifies that the unit is operational and avoids nuisance trouble
conditions caused by holidays, vacations, etc.

11.0 Other Information

11.1 Anti-vandal Tie-down

• After the cover has been installed and twisted into place, the

entire assembly can be secured together using the supplied
anti-vandal screws. There are two of them; one for each side
(see drawings on page 1 for the location of the screw holes).

11.2 Anti-tamper Screws for EN50131 Applications

• After the enclosure assembly has been installed to the mount-

ing base, the entire assembly can be secured together using
the supplied anti-tamper screws. The anti-tamper screws are
required for EN50131 applications. There are two of them; one
for each side (see drawings on page 1 for the location of the
screw holes).

11.3 Optical Module Masking

• Peel-off masks are provided with the unit for each segment of

the optical module to allow for customized coverage, or to block
out areas of objects that may cause thermal disturbances. The
mask is self-adhesive and pre-cut in the shape of the optical
module.

• To block out a particular zone or group of zones, peel off a

section of the mask that corresponds to the appropriate zone,
and stick it on the mirror segment. Use Section 13.0 (DS938Z
Mirror Module to Pattern Reference) to identify mirror segments
and zones.

11.4 Maintenance

• At least once a year, the range and coverage should be checked

according to Sections 7.0 and 8.0 (Setup and Walk Testing and
Final Tests).

• To ensure continued daily operation, the end user should be

instructed to daily walk through the far end of the coverage
pattern. This assures an alarm output prior to arming the
system.

11.5 Reading Bosch Security Systems, Inc. Product Date Codes

For Product Date Code Information. refer to the Bosch Security
Systems, Inc. Web site at: http://www.boschsecurity.com/
datecodes.

12.0 Typical Placements to Achieve Coverage

13.0 Optical Masking to Avoid Environmental Problems

3

2

1

1

2

3

4

5

BASEBOARD HEAT

AR8-13

4

3

2

1

5

4 3 2 1

MASK 3

SECTORS

AR8-13

4

3

2

1

5

4 3 2 1

MASK 15

SECTORS

WINDOW

1

1

2

3

4

5

14.0 DS938Z Mirror Module to Pattern Reference

M-4

AR8-13

D

4

3

2

1

4 3

1

2

5

A

B

P

C

E

F

G

H

I

J

N

O

K

L

M

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

TOP VIEW

M-3

M-2

M-1

E-1

E-2

E-3

E-4

5

SIDE VIEW

NOTE:

The location of the zone to be masked depends on the position of
the detector. Therefore, determine the mirror surface to be
masked before removing the mirror from the detector. When
replacing the mirror, make sure it is facing the same direction as
before it was removed.

Before attempting any masking, be sure the chosen mirror
surface is the correct one. When attempting to remove any
masking, many adhesives will either destroy the mirror surface or
leave enough residue behind to reduce coverage performance.

When disabling the look-down segment, do not mask segment 5
directly as this will disable the entire detector. Instead, mask the
segment on the dome directly below segment 5.

Avoid soiling or leaving fingerprints on the mirror surfaces.
Should they become soiled or otherwise marked, they can be
cleaned using a soft, clean cloth and any commonly available mild
window cleaner.

Drawings are not to scale and are intended as
pattern identifiers only.

Содержание DS938Z

Страница 1: ... looking straight down from the unit sabotage Each barrier is 30 ft 9 2 m long and 4 4 ft 1 3 m wide at 30 ft 9 2 m Choice of two optical modules depending on ceiling height NOTE For UL Certificated installations the coverage is 360 by 54 ft 16 5 m when mounted from 10 to 13 ft 3 1 to 4 0 m using the AR8 13 Array and when mounted from 15 to 18 ft 4 6 to 5 5 m using the AR13 18 Array Input Power 6 ...

Страница 2: ... the Optical Module AR8 13 or AR13 18 Replace the enclosure onto the base For ceilings between 8 and 13 ft 2 4 and 4 0 m from the floor use the optical module marked AR8 13 This marking can be found next to the two optical module tabs For ceilings between 13 and 18 ft 4 0 and 5 5 m high use the optical module marked AR13 18 To replace an optical module push the optical module tabs towards the cent...

Страница 3: ...espect to either outside pin outside pins are common Place the cover on the unit and twist lock it clockwise into place NOTE Be sure the TC6000 and Sonalert leads are dressed through the cutout Apply power to the unit Wait at least two minutes after applying power to start walk tests NOTE Walk testing should be done across the coverage pattern as shown The edge of the coverage pattern is determine...

Страница 4: ...ovided with the unit for each segment of the optical module to allow for customized coverage or to block out areas of objects that may cause thermal disturbances The mask is self adhesive and pre cut in the shape of the optical module To block out a particular zone or group of zones peel off a section of the mask that corresponds to the appropriate zone and stick it on the mirror segment Use Secti...