Bosch DS935LSN Скачать руководство пользователя страница 4

Page 4  P/N: 47885F 3/04 

 

DS935 LSN Installation Instructions 

 

Only apply power after all connections have been 
made and inspected. 

 

 

 

 

• 

Connect shielded cable to the T-strip as shown: 

 
Terminal Descriptions 

• 

aLSN1 & bLSN1: coming from the preceding LSN element. 

Use shielded cable for bus connections. 

• 

aLSN2 & bLSN2: going to the next LSN element. Use 

shielded cable for bus connections. 

• 

5&6: Spare terminals. 

• 

7: Connection for ground wire from shielded cable. 

NOTE:  Do not coil excess wire inside the enclosure and seal 

the wire entrance with the plug provided. 

3.0 Adjust Sensitivity 

• 

Set the sensitivity to one of the following settings using the 
software: 
Standard: The recommended setting for maximum false 
alarm immunity. Tolerates environmental extremes on this 
setting. Standard Sensitivity is not recommended for Long 
Range patterns. The detector is shipped in Standard 
Sensitivity mode. 

Intermediate: The recommended setting for any location 
where an intruder is expected to cover only a small portion of 
the protected area or when quick catch performance is 
desired. Tolerates normal environments on this setting. This 
setting will improve intruder catch performance. 

4.0 Setup and Walk Testing 

• 

Replace the cover and insert the tamper screw if desired. 

• 

Apply power to the unit. 

• 

Wait for approximately two minutes with no motion in the 
coverage area, then begin walk testing. 

 

 
 
NOTE:  
Walk test across the 

pattern. 

 

 

 

• 

The edge of the coverage is determined by activation of the 
LED. 

• 

Walk test the unit from both directions to determine the 
boundaries. 

• 

If the desired range cannot be achieved, try angling the mirror 
up or down to assure the coverage pattern is not aimed too 
high or too low. 

• 

If required, install the security seal (P/N 3.102.389.687) 
across the gap between the base and cover just beside the 
Cover Locking Screw. 

5.0 Other Information 

Maintenance: At least once a year, the range and coverage 
should be checked in accordance with the walk test section. 
To ensure continual daily operation, the end user should be 
instructed to daily walk through the outer edge of the 
coverage area and observe the LED operation (if used.) This 
assures an alarm output prior to arming. 

Masking: Per VdS requirements, masking of lens sections is 
to be avoided.  The masking materials impair the reported de-
tector performance. Furthermore, any pollution or staining of 
the mirror can degrade detector performance, and is to be 
avoided.  

6.0 Coverage Patterns 

NOTE:  All dimensions in meters. 

A

B

C D E

Mirror Segment to
Pattern Reference

Curtain Coverage

0

1.5

2

Top view

21

1.5

0

21

0

0

3

0

21

21

0

0

0

1.5

1.5

Side view

Mirror adjusted to -3°

A

E

D

C

B

 

 

 

aL

S

N

1

aL

S

N

2

bLS

N1

bL

SN2

SP

ARE

SP

A

R

E

SH

E

IL

D

Mirror Segment to
Pattern Reference

A B C D E F G H

I

J

K

L M N

O P Q

11

0

0

0

5.5

5.5

5.5

5.5

Top view

Wide Angle Coverage

11

B

A

D

C

E

G

F

H

I

J

K

L

M

N

P

Q

O

0

Q

0

3

2

Side view

Mirror adjusted to -6°

11

11

0

0

O-

J -N

A -I

Содержание DS935LSN

Страница 1: ... vorzugehen Montage an Wänden oder Ecken Stoßen Sie zwei vorgestanzte Öffnungen im Gehäuse durch Verwenden Sie das Gehäuse als Bohrschablone um die Lage der Befestigungsschrauben zu markieren Hinweis Je nach der Beschaffenheit der Wand ist das entsprechende Befestigungsmaterial zu verwenden z B Dübel usw Montieren Sie den Melder und prüfen Sie dessen festen Sitz Setzen Sie den Spiegel und die Leit...

Страница 2: ...bssicherheit sollte der Überwachungsbereich des Bewegungsmelder durch Gehtest auf Abweichung vom Betreiber täglich überprüft werden sofern die Funktion Gehtest für den Betreiber einstellbar ist Bei jeder Inspektion durch die Wartungsfirma muß der Überwachungsbereich auf Abweichungen von der im Installationsattest dokumentierten Bereichen hin überprüft werden Maskierung Nach den VdS Richtlinien ist...

Страница 3: ...olid and free of vibration Remove the cover by inserting a thin flat blade screwdriver into the notch at the bottom of the cover and prying up Remove the circuit board by pressing a circuit board retainer tab toward the side of the enclosure and lifting the circuit board up and out of the enclosure base Remove the mirror by sliding it out of its tracks NOTE To change the mirror simply remove the c...

Страница 4: ... begin walk testing NOTE Walk test across the pattern The edge of the coverage is determined by activation of the LED Walk test the unit from both directions to determine the boundaries If the desired range cannot be achieved try angling the mirror up or down to assure the coverage pattern is not aimed too high or too low If required install the security seal P N 3 102 389 687 across the gap betwe...

Отзывы: