Bosch DS935LSN Скачать руководство пользователя страница 3

DS935 LSN Installation Instructions 

 

P/N: 47885F 3/04  Page 3 

 Installation Instructions 

for the DS935LSN 

ASIC-Based PIR Intrusion Detector 

1.0 Specifications 

LSN Supply Voltage: 

33 V maximum 

LSN Current Consumption: 

0.8 mA 

Coverage: 

Wide Angle Mirror: 

11 m by 11 m 

Curtain Mirror: 

21 m by 3 m 

Walking Speeds: 

Wide Angle Mirror: 

0.2 m/s to 3.0 m/s 

Curtain Mirror: 

0.2 m/s to 4.0 m/s 

Sensitivity: 

Standard or Intermediate 

Ambient Conditions: 

Storage Temperature: 

-20°C to +60°C 

Operating Temperature: 

-10°C to +55°C 

Air humidity (EN60721): 

<95% rH, non-condensing 

Housing Protection        
(EN60529, EN50102): 

IP41 / IK02 

VdS Environment Class: 

II 

VdS Approval, class B: 

G101552 

with Curtain Mirror: 

G101553 

Options: 

B338 Ceiling Mount Bracket, 
OMLR93-3 Curtain Mirror 

NOTE:  Misalignment of the detector when using an optional 

mounting bracket may reduce range. 

2.0 Mounting 

aL

S

N

1

aL

SN

2

bL

S

N

1

bLSN2

SP

AR

E

SP

A

R

E

SH

EI

LD

T-Strip

Tamper Switch

LED

Location of major items -

Circuit Board

Securing Screw

Corner
Mounting
Holes (2)

Surface

Mounting
Holes (4)

Bracket Mounting

Hole

Mirror
Tracks (2)

Circuit Board

Retainer Tabs (2)

Rear enclosure and mounting holes

Wiring
Knockouts

Cable Tie/
Strain Relief

 

Things to Avoid/Remember 

Avoid 

Direct hot and/or cold drafts 

Windows 

Small animals 

Air conditioning outlets 

Heat sources 

Direct sunlight 

Remember 

Won’t detect through glass 

Best catch performance is across the pattern 

When using two or more detectors, cross the patterns for best coverage

 

 

• 

Select a location that is most likely to intercept an intruder 
moving across the coverage pattern. 

• 

The recommended mounting height range is 2 m to 2.6 m. 

NOTE:  The mounting surface should be solid and free of 

vibration. 

• 

Remove the cover by inserting a thin, flat blade screwdriver 
into the notch at the bottom of the cover and prying up. 

• 

Remove the circuit board by pressing a circuit board retainer 
tab toward the side of the enclosure and lifting the circuit 
board up and out of the enclosure base. 

• 

Remove the mirror by sliding it out of its tracks. 

NOTE:  To change the mirror, simply remove the current mirror 

and slide the other mirror into the tracks. 

• 

Open an appropriate wiring knockout and route the wiring 
through.  

• 

For strain relief, attach the cable to the Cable Tie / Strain 
Relief with the plastic tie-down supplied. 

• 

Follow the procedure below for surface mounting, corner 
mounting, or bracket mounting. 

Surface or Corner Mounting 

• 

Open two holes for either surface or corner mounting. 

• 

Using the enclosure as a template, mark the location for the 
mounting screws. 

NOTE:  Depending on the surface, choose appropriate 

mounting hardware (e.g., anchors, etc.) 

• 

Firmly mount the detector. 

• 

Replace the mirror and circuit board. 

Bracket Mounting 

• 

Mount the bracket to the mounting surface using the mounting 
instructions that come with the bracket. 

• 

Knockout the bracket mounting hole in the enclosure base 
and attach the enclosure to the bracket using the mounting 
instructions that come with the bracket. 

• 

Replace the mirror and circuit board. 

Select the Vertical Angle 
NOTE:
  The vertical angle adjustment markings are on the 

mirror. 

 

• 

Determine the appropriate vertical angle for the installation 
using the following chart: 

 
Mounting Height 

Wide Angle Mirror 

Curtain Mirror 

2.0 m 

-6° 

-2° 

2.3 m 

-8° 

-2° 

2.6 m 

-10° 

-4° 

 

• 

Slide the mirror forward or backward until the appropriate 
angle hash marks are in-line with the marks on each side of 
the frame. 

NOTE:  Excessive handling of the mirror surface may lead to 

performance degradation. 

 

-16

-8

0

+2

Mirror

+2

0

-8

-16

+2

0

-8
-16

Содержание DS935LSN

Страница 1: ... vorzugehen Montage an Wänden oder Ecken Stoßen Sie zwei vorgestanzte Öffnungen im Gehäuse durch Verwenden Sie das Gehäuse als Bohrschablone um die Lage der Befestigungsschrauben zu markieren Hinweis Je nach der Beschaffenheit der Wand ist das entsprechende Befestigungsmaterial zu verwenden z B Dübel usw Montieren Sie den Melder und prüfen Sie dessen festen Sitz Setzen Sie den Spiegel und die Leit...

Страница 2: ...bssicherheit sollte der Überwachungsbereich des Bewegungsmelder durch Gehtest auf Abweichung vom Betreiber täglich überprüft werden sofern die Funktion Gehtest für den Betreiber einstellbar ist Bei jeder Inspektion durch die Wartungsfirma muß der Überwachungsbereich auf Abweichungen von der im Installationsattest dokumentierten Bereichen hin überprüft werden Maskierung Nach den VdS Richtlinien ist...

Страница 3: ...olid and free of vibration Remove the cover by inserting a thin flat blade screwdriver into the notch at the bottom of the cover and prying up Remove the circuit board by pressing a circuit board retainer tab toward the side of the enclosure and lifting the circuit board up and out of the enclosure base Remove the mirror by sliding it out of its tracks NOTE To change the mirror simply remove the c...

Страница 4: ... begin walk testing NOTE Walk test across the pattern The edge of the coverage is determined by activation of the LED Walk test the unit from both directions to determine the boundaries If the desired range cannot be achieved try angling the mirror up or down to assure the coverage pattern is not aimed too high or too low If required install the security seal P N 3 102 389 687 across the gap betwe...